Operation 2. Common Functions
RC700-A option TP3 Rev.8
35
2.3 Tool
Tap the icon button to display the each tool menu.
The displayed icons differ depending on the currently used panel.
2.3.1 I/O Monitor
Tap
to display the [I/O Monitor] panel.
Inputs/outputs and memory I/O of the Controller can be monitored.
Inputs and outputs can be displayed at the same time. Bit, Byte, and Word can be
selected.
Bit shows the I/O status and labels.
Byte and Word show values and labels.
Checking the [Hexadecimal Values] checkbox displays the byte and word values in
hexadecimal notation. Unchecking the checkbox displays the values in decimal notation.
Tapping [Status] of the bit you want to change with the Enable switch ON changes
ON/OFF of the output bits. However, ON/OFF cannot be changed if the [I/O Monitor]
panel is opened from the following panels:
[Test] panel [Operator Panel] panel
Statuses of the selected inputs are continuously updated, while outputs are updated when
the output bits are changed.
The I/O can be searched by the I/O label.
Enter the text to search and tap the search button. You can search through the currently
displayed list.