![Epson TM-300A Operator'S Manual Download Page 45](http://html.mh-extra.com/html/epson/tm-300a/tm-300a_operators-manual_2418720045.webp)
[Default]
n = 0
[Reference]
See APPENDIX G Character Code Table
ESC U
n
[Name]
[Format]
[Range]
[Description]
[Notes]
[Default]
ESC c 3 n
Set/cancel uni-directional printing
<1B>H<55>H<n>
0 n 255
Sets or cancels uni-directional printing.
l
Only the lowest bit of
n
is valid.
When
n
= <* * * * * * * 1>B, uni-directional printing is set.
When
n
= < * * * * * * * 0>B, uni-directional printing is can-
celed. (And bi-directional printing is set.)
l
When uni-directional printing is set, the printer prints from left to
right.
l
When the user wants to avoid horizontal misalignment, this
command should be used to select uni-directional printing.
(Double-height printing, line printing, and so on.)
n = 0
[Name]
Selects the paper-end detectors that will control the paper-end
signal
[Format]
<1B>H<63>H<33>H<n>
[Range]
0 n 255
[Description]
This command is supported only by the TM-300PA/PB.
Selects paper detectors to output signals on the paper-end status
line.