The same as the internal character set.
l
Horizontally adjacent dots cannot be printed.
l
Only the top bit is valid in the secondary data bytes in the ver-
tical direction.
ESC %
l
7 X 9 font
PI P3 p5 p7 p9 p11 p13 p15 p17
p 1 9
When the dot pattern for code 20H is defined as shown above.
ESC & s n m
a
P
1
p2 p3 p4 p5 p6 p7 p8 p9 p10 p11 p12 p13 p14
coda (Hexadecimal)
18
26 02 20 20 07 1F 80 20 00 44 00 80 00 44
00
20
00
1F
80
(The corresponding bit is 1 when printing, and 0 when not printing.)
ESC *
mn1 n2 [d] n1 + 256 X n2
[Name]
Set bit image mode
[Format]
<1B>H<2A>H<m><n1><n2>[<d>]n1+256Xn2
[Range]
m = 0, 1
0 n 2 3
0 n 1 2 5 5
0 d 255
[Description]
Sets the bit image mode using m and the number of dots using
n1
and
n2.
l
Divide the number of dots to be printed by 256. The integer
answer is n2 and the remainder is n1 . Therefore, the number of
dots in the horizontal direction is calculated as : n1 + 256 X n2.
• If the bit image data input exceeds the number of dots to be
printed on a line, the excess data is ignored.
l
"d" indicates the bit image data. Set a corresponding bit to 1 to
print a dot, otherwise set it to 0.