3.2.4.18 CR servo parameter error (0001001D)
Explanation:
There may be a case where a voltage exceeding the specified value is about to be
applied to the CR Motor. In such a case, this message is displayed and the printer
stops operating.
Cause of trouble:
•
A small PWM output is kept on for a certain period of time (load is kept
applied).
•
Carriage related mechanism out of step or carriage bumped.
Points to be checked:
1.
The CR Encoder and the T Fence must be free from dust and dirt or any other
foreign matters.
2.
The CR Timing Belt must be free from any defects and the belt must be in
proper tension.
3.
The carriage must slide smoothly, free from undue load.
4.
Measure the resistance value of the CR Motor.(5.8
Ω
)
If the CR Motor is found in short mode, replace the C472MAIN Board at the
same time.
5.
Execute encoder checking by
“5.2.2.4 Encoder
”(p225)
in the self-
diagnostics menu.
6.
All the harness must be connected properly and free from short circuit or
broken wire.
Remedy:
•
Replace the
MAIN Board (C472 MAIN)
(p.207).
•
Replace the
CR Encoder Sensor ASSY
(p.178).
(Refer to
“CR Encoder Sensor Mounting Position Adjustment”
(p.268)
)
•
Replace the
CR Motor ASSY
(p.180).
(Refer to
“CR Timing Belt Tension Adjustment”
(p.263)
)
•
Make the mechanism adjustment for the carriage-related mechanism.
•
Remove the foreign matters.
3.2.4.19 PF servo parameter error (0001001E)
Explanation:
There may be a case where a voltage exceeding the specified value is about to be
applied to the PF Motor. In such a case, this message is displayed and the printer
stops operating.
Cause of trouble:
•
A small PWM output is kept on for a certain period of time (load is kept
applied).
•
Paper feed related mechanism out of step.
Points to be checked:
1.
The PF Encoder and the PF Loop Scale must be free from dust and dirt or any
other foreign matters.
2.
The PF Timing Belt must be free from any defects and the belt must be in
proper tension.
3.
The grid roller must rotate smoothly, free from undue load.
4.
Measure the resistance value of the CR Motor.(5.8
Ω
)
If the CR Motor is found in short mode, replace the C472MAIN Board at the
same time.
5.
Execute encoder checking by
“5.2.2.4 Encoder
”(p225)
in the self-
diagnostics menu.
6.
All the harness must be connected properly and free from short circuit or
broken wire.
Remedy:
•
Replace the
MAIN Board (C472 MAIN)
(p.207).
•
Replace the
PF Encoder Sensor ASSY
(p.186).
(Refer to
PF Encoder Sensor Installation Position Adjustment
(p.272)
)
•
Replace the
PF Motor
(p.185).
(Refer to
PF Timing Belt Tension Adjustment
(p.264)
)
•
Clear the cause of paper feed related mechanism out-of-step.
Summary of Contents for Stylus Pro 7600 Photographic Dye Ink
Page 1: ...EPSONStylusPro7600 9600 Color Large Format Inkjet Printer SERVICE MANUAL SEIJ01017 ...
Page 5: ...Revision Status Revision Date of Issue Description A May 10 2002 First release ...
Page 11: ...C H A P T E R 1 PRODUCTDESCRIPTION ...
Page 100: ...C H A P T E R 2 OPERATINGPRINCIPLES ...
Page 121: ...C H A P T E R 3 TROUBLESHOOTING ...
Page 151: ...C H A P T E R 4 DISASSEMBLY ASSEMBLY ...
Page 210: ...C H A P T E R 5 ADJUSTMENT ...
Page 274: ...C H A P T E R 6 MAINTENANCE ...
Page 281: ...C H A P T E R 7 APPENDIX ...
Page 287: ......
Page 288: ......
Page 289: ......
Page 290: ......
Page 291: ......
Page 292: ...EPSON Stylus Pro 7600 9600 Revision A Appendix Exploded Diagrams 292 7 4 Exploded Diagrams ...
Page 304: ...851 850 854 Rev 01 C472 MECH 081 PX 7000 EPSON STYLUS PRO 7600 No 12 853 853 855 851 856 ...
Page 315: ...851 850 854 Rev 01 C473 MECH 081 PX 9000 EPSON STYLUS PRO 9600 No 12 853 853 855 851 856 ...