CHAPTER 8: DEBUGGER
S5U1C63000A MANUAL
EPSON
181
(S1C63 FAMILY ASSEMBLER PACKAGE)
(4) During log mode
If the program is single-stepped after turning on the log mode, the same contents as when executing
the rd command are displayed in the [Command] window after each step is completed.
Notes
• The step count must be specified within the range of 0 to 65,535. An error results if the limit is ex-
ceeded.
Error : Number of steps out of range, use 0-65535
• If the [Data] window is opened, its display contents are updated after the execution.
• During a single-step operation, the program will not break even if the break condition set by a
command is met.
• Unlike in successive executions (g or gr command), the [Register] window is updated every time a
step is executed.
GUI utility
[Run | Step] menu item, [Step] button
When this menu item or button is selected, the s command without step count is executed.
[Step] button