IV ANALOG BLOCK: A/D CONVERTER
S1C33210 FUNCTION PART
EPSON
B-IV-2-15
Programming Notes
(1) Before setting the conversion mode, start/end channels, etc. for the A/D converter, be sure to disable the A/D
converter (ADE (D2) / A/D enable register (0x40244) = "0"). A change in settings while the A/D converter is
enabled could cause it to operate erratically.
(2) The A/D converter operates only when the prescaler is operating.
When the A/D converter registers are set up, the prescaler must be operating. Therefore, start the prescaler first
and make sure the A/D converter is supplied with its operating clock before setting up the A/D converter
registers.
In consideration of the conversion accuracy, we recommend that the A/D converter operating clock be min. 32
kHz to max. 2 MHz.
(3) Do not start an A/D conversion when the clock supplied from the prescaler to the A/D converter is turned off,
and do not turn off the prescaler's clock output when an A/D conversion is underway, as doing so could cause
the A/D converter to operate erratically.
(4) After an initial reset, the interrupt factor flag (FADE) becomes indeterminate. To prevent generation of an
unwanted interrupt or IDMA request, be sure to reset this flag and register in a program.
(5) To prevent the regeneration of interrupts due to the same factor following the occurrence an interrupt, always
be sure to reset the interrupt factor flag before setting the PSR again or executing the reti instruction.
(6) When the A/D converter is set to enabled state, a current flows between AV
DD
and V
SS
, and power is
consumed, even when A/D operations are not performed. Therefore, when the A/D converter is not used, it
must be set to the disabled state (default "0" setting of ADE(D2) in the A/D enable register (0x40244)).
(7) Once A/D conversion ends, further A/D conversion will not be performed correctly if restarted within an
interval shorter than one cycle of the A/D converter operating clock set by the prescaler.
(8) When the 8-bit programmable timer 0 underflow signal or the 16-bit programmable timer 0 compare match B
signal is used as a trigger factor, the division ratio of the prescaler used by the relevant timer must not be set to
θ
/
1
.
(9) ADD[9:0] is read out in two operations; one to read out the lower 8 bits and another to read out the upper 2 bits.
When multiple channels are used in continuous or normal mode, it is possible for ADD[9:0] to be overwritten
with a new conversion result between the first and the second of these read operations. In this case, the lower 8
bits and the upper 2 bits will each be from different conversion operations, and the value will be invalid.
Applications must take steps to assure this does not occur.
Note that OWE will be set to "1" if ADD[9:0] is overwritten between the first read operation and the second
read operation on the first readout after a conversion completes (readout in the state where the conversion
completion flag, ADF, is "1").
However, if the same conversion result is read out multiple times, when data that has already been read out is
read out again (readout in the state where the conversion completion flag, ADF, is "0"), OWE will not be set to
"1" when ADD[9:0] is overwritten between the two read operations.
Summary of Contents for S1C33210
Page 4: ......
Page 13: ...S1C33210 PRODUCT PART ...
Page 14: ......
Page 124: ...APPENDIX B PIN CHARACTERISTICS A 110 EPSON S1C33210 PRODUCT PART THIS PAGE IS BLANK ...
Page 125: ...S1C33210 FUNCTION PART ...
Page 126: ......
Page 127: ...S1C33210 FUNCTION PART I OUTLINE ...
Page 128: ......
Page 130: ...I OUTLINE INTRODUCTION B I 1 2 EPSON S1C33210 FUNCTION PART THIS PAGE IS BLANK ...
Page 138: ...I OUTLINE LIST OF PINS B I 3 6 EPSON S1C33210 FUNCTION PART THIS PAGE IS BLANK ...
Page 139: ...S1C33210 FUNCTION PART II CORE BLOCK ...
Page 140: ......
Page 142: ...II CORE BLOCK INTRODUCTION B II 1 2 EPSON S1C33210 FUNCTION PART THIS PAGE IS BLANK ...
Page 148: ...II CORE BLOCK CPU AND OPERATING MODE B II 2 6 EPSON S1C33210 FUNCTION PART THIS PAGE IS BLANK ...
Page 152: ...II CORE BLOCK INITIAL RESET B II 3 4 EPSON S1C33210 FUNCTION PART THIS PAGE IS BLANK ...
Page 234: ...II CORE BLOCK CLG Clock Generator B II 6 10 EPSON S1C33210 FUNCTION PART THIS PAGE IS BLANK ...
Page 236: ...II CORE BLOCK DBG Debug Unit B II 7 2 EPSON S1C33210 FUNCTION PART THIS PAGE IS BLANK ...
Page 237: ...S1C33210 FUNCTION PART III PERIPHERAL BLOCK ...
Page 238: ......
Page 240: ...III PERIPHERAL BLOCK INTRODUCTION B III 1 2 EPSON S1C33210 FUNCTION PART THIS PAGE IS BLANK ...
Page 296: ...III PERIPHERAL BLOCK WATCHDOG TIMER B III 5 4 EPSON S1C33210 FUNCTION PART THIS PAGE IS BLANK ...
Page 429: ...S1C33210 FUNCTION PART IV ANALOG BLOCK ...
Page 430: ......
Page 432: ...IV ANALOG BLOCK INTRODUCTION B IV 1 2 EPSON S1C33210 FUNCTION PART THIS PAGE IS BLANK ...
Page 448: ...IV ANALOG BLOCK A D CONVERTER B IV 2 16 EPSON S1C33210 FUNCTION PART THIS PAGE IS BLANK ...
Page 449: ...S1C33210 FUNCTION PART V DMA BLOCK ...
Page 450: ......
Page 452: ...V DMA BLOCK INTRODUCTION B V 1 2 EPSON S1C33210 FUNCTION PART THIS PAGE IS BLANK ...
Page 506: ...V DMA BLOCK IDMA Intelligent DMA B V 3 18 EPSON S1C33210 FUNCTION PART THIS PAGE IS BLANK ...
Page 507: ...S1C33210 FUNCTION PART Appendix I O MAP ...
Page 508: ......
Page 557: ......