![Epson S1C17 Series Manual Download Page 117](http://html.mh-extra.com/html/epson/s1c17-series/s1c17-series_manual_107781117.webp)
7-58
Seiko Epson Corporation
S1C17 CORE MANUAL
(REV. 1.2)
ld %rd, sign7
Function
16-bit data transfer
Standard)
rd
(6:0)
←
sign7
(6:0),
rd
(15:7)
←
sign7
(6),
rd
(23:16)
←
0
Extension 1)
rd
(15:0)
←
sign16
(15:0),
rd
(23:16)
←
0
Extension 2) Unusable
Code
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
1 0 0 1 1 0
r d
sign7
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Flag
IL IE C V Z N
– – – – – –
|
|
|
| |
Mode
Src: Immediate data (signed)
Dst: Register direct
%rd
=
%r0
to
%r7
CLK
One cycle
Description
(1) Standard
ld %rd,sign7
; rd
←
sign7 (sign-extended)
The 7-bit immediate
sign7
is loaded to the
rd
register after being sign-extended to a 16-bit
quantity.
(2) Extension 1
ext imm13
; = sign16(15:7)
ld %rd,sign7 ;
rd
←
sign16, sign7 = sign16(6:0)
The immediate data is extended into a 16-bit quantity by the
ext
instruction and it is loaded to
the
rd
register.
(3) Delayed slot instruction
This instruction may be executed as a delayed slot instruction by writing it directly after
a branch instruction with the “d” bit. In this case, extension of the immediate by the
ext
instruction cannot be performed.
Example
ld %r0,0x7f
; r0
←
0xffff (r0 = 0x00ffff)