Maintenance 6. Maintenance Parts Replacement Procedures
168
RC620 Rev.8
BIOS
Backup Battery
(Normal)
Installation
(1) Place a battery on the battery holder on
the CPU board.
Push down the battery until it is firmly
secured with latch.
Make sure the latch is in the same state
as shown in the photo.
Latch
Battery holder
(2) Mount the CPU board.
Refer to
Maintenance: 6.4.1.1 CPU Board (Normal)
.
(3) Connect the following items to the
Controller.
Keyboard
Mouse
Display
Power plug
Connect the keyboard with PS/2 port of
the CPU board.
If you use the USB keyboard, connect
it with PS/2 port using PS/2 branch
cable (attached to the Controller).
(4) Turn ON the Controller power and keep pressing the <Delete> key.
BIOS window will be displayed.
(5) Change the BIOS setting as below.
Select the [Integrated Peripherals] from the Main menu.
NOTE
NOTE