4.4.2 Linear Scale
Parts/Components need to be removed in advance
Upper Housing / Scanner Unit / Panel Unit / M/B Cover / Waste Ink Tray Assy /
Middle Housing
Removal procedure
1.
Remove the spring from the left frame of the printer.
2.
Release the Linear Scale from the hook at the right frame of the printer.
3.
Pull out the Linear Scale from the CR Encoder of the CR Unit.
4.
Turn the Linear Scale upward by 90 degrees and release it from the left hook.
Figure 4-57. Removing the Linear Scale
C A U T I O N
When you hold the Linear Scale, hold its ends or two points of
the top and bottom surfaces with your hands; do not touch the
reading surface.
Take care that the reading surface is not soiled or scratched.
Especially when putting the Linear Scale through the CR
Encoder during reassembly work, take great care that grease of
the CR Guide Shafts does not adhere to the reading surface.
C H E C K
P O I N T
If you need to move the Carriage Unit, unlock the Carriage in
advance.
(
See
4.1.5 How to Unlock the Carriage (p.62)
.)
CR_Scale02.eps
About 25mm
About 45mm
Hold here
Hold here
Hold here
Hold here
Install the Linear Scale with the cutting portion upward.
Step 1. Remove the spring
Step 2. Release it from the hook
Step 3. Pull it out from CR Encoder
CR Unit
Step 4. Turn it by 90 degrees and release it
Cutting Portion
Summary of Contents for PX650 Series
Page 9: ...Confidential C H A P T E R A 1 PRODUCTDESCRIPTION ...
Page 34: ...Confidential C H A P T E R 2 OPERATINGPRINCIPLES ...
Page 41: ...Confidential C H A P T E R 3 TROUBLESHOOTING ...
Page 60: ...Confidential C H A P T E R 4 DISASSEMBLYANDASSEMBLY ...
Page 110: ...Confidential C H A P T E R 5 ADJUSTMENT ...
Page 130: ...Confidential C H A P T E R 6 MAINTENANCE ...
Page 138: ...Confidential C H A P T E R 7 APPENDIX ...
Page 140: ...Confidential C H A P T E R 8 EpsonStylusPhotoPX660 PX660Premium Artisan635 ...