Epson Stylus Photo PX650/TX650/TX659/PX660/PX660 Premium/Artisan 635
Revision C
DISASSEMBLY AND ASSEMBLY
Disassembly of Scanner Unit
107
Confidential
4.5.2 CIS Unit
Parts/Components need to be removed in advance
Upper Housing / Scanner Unit / Scanner Housing
Removal procedure
1.
Disconnect the FFC from the connector of the CIS unit.
2.
Turn the CIS Unit by 90 degrees upward, and remove the CIS Unit from the right
and left shaft holes of the carriage.
Figure 4-111. Removing the CIS Unit
C A U T I O N
Take care in handling the Lower Housing because grease is
applied to the CR guide area of the Lower Housing.
Do not touch any parts with a greasy hand or part.
Remove by turning it by 90 degrees.
CIS Unit
CIS Carriage
FFC
When replacing the CIS Unit, check the sticker on the Bottom
Board, and use the spacers (x2) of the same letter (A - C) as the
marking on the sticker, placing them at the right and left
positions.
Figure 4-112. Installing the CIS Unit (1)
When installing the Timing Belt, align the side that has teeth of
the Timing Belt with the tooth of the CIS Unit, then secure
them with the Belt Clamp.
Installing the CIS Unit (2)
Bottom of CIS
Install the spacers (x2) of the same
letter (A - C) as the marking on the
sticker, placing them at the right
and left positions.
A: Spacer, CIS, A17 (black)
B: Spacer, CIS, B19 (white)
C: Spacer, CIS, C21 (gray)
Sticker
Spacer, CIS, B
Belt Clamp
Toothed area
Timing Belt
Bottom of CIS
Summary of Contents for PX650 Series
Page 9: ...Confidential C H A P T E R A 1 PRODUCTDESCRIPTION ...
Page 34: ...Confidential C H A P T E R 2 OPERATINGPRINCIPLES ...
Page 41: ...Confidential C H A P T E R 3 TROUBLESHOOTING ...
Page 60: ...Confidential C H A P T E R 4 DISASSEMBLYANDASSEMBLY ...
Page 110: ...Confidential C H A P T E R 5 ADJUSTMENT ...
Page 130: ...Confidential C H A P T E R 6 MAINTENANCE ...
Page 138: ...Confidential C H A P T E R 7 APPENDIX ...
Page 140: ...Confidential C H A P T E R 8 EpsonStylusPhotoPX660 PX660Premium Artisan635 ...