EPSON Perfection V10/V100 Photo/V200 Photo/V350 Photo
Revision B
TROUBLESHOOTING
Troubleshooting
29
Table 3-8. The Fluorescent Lamps does not light up (the Main Unit).
Step
Cause
Point to be checked
Result
Corrective Action
1
The Carriage FFC is
disconnected from the Main
Board.
Is the Carriage FFC
disconnected from the Main
Board?
Yes
Connect the FFC.
2
The Carriage Unit failure.
—
Yes
Replace the Carriage Unit
with a new one.
3
Main Board failure.
—
Yes
Replace the Main Board with
a new one.
Table 3-9. The Fluorescent Lamps does not light up (TPU).
Step
Cause
Point to be checked
Result
Corrective Action
1
The connector of the
Fluorescent Lamp is
disconnected from the TPU
Inverter Board.
Is the connector of the
Fluorescent Lamp
disconnected from the TPU
Inverter Board?
Yes
Connect the connectors.
2
The TPU Inverter Board
failure.
—
—
Replace the TPU Inverter
Board with a new one.
to 4.4.2 Harness TPU/TPU
Inverter Board P44)
3
Main Unit Main Board
failure.
—
—
Replace the Main Board with
a new one.
Table 3-10. The films are not fed or ejected (AFL).
Step
Cause
Point to be checked
Result
Corrective Action
1
The connector of the AFL
Sensor A is disconnected
from the AFL Main Board.
Is the connector of the AFL
Sensor A disconnected from
the AFL Main Board?
Yes
Connect the connectors.
2
The AFL Motor connector is
disconnected from the AFL
Main Board.
Is the AFL Motor connector
disconnected from the AFL
Main Board?
Yes
Connect the connectors.
3
The connector of the AFL
Sensor B is disconnected from
the AFL Main Board.
Is the connector of the AFL
Sensor B disconnected from
the AFL Main Board?
Yes
Connect the connectors.
4
The AFL Main Board failure.
—
—
Replace the AFL Main Board
with a new one.
4.5.2 Harness AFL/AFL Main
Board P47)
5
Main Unit Main Board
failure.
—
—
Replace the Main Board with
a new one.
Table 3-11. The Fluorescent Lamps does not light up (AFL).
Step
Cause
Point to be checked
Result
Corrective Action
1
The connector of the
Fluorescent Lamp is
disconnected from the AFL
Inverter Board.
Is the connector of the AFL
Fluorescent Lamp
disconnected from the AFL
Inverter Board?
Yes
Connect the connectors.
2
The AFL Inverter Board and
the AFL Main Board are not
connected by the connector
cable.
The AFL Inverter Board and
the AFL Main Board are not
connected by the connector
cable?
Yes
Connect the connectors.
3
The AFL Main Board failure.
—
—
Replace the AFL Main Board
with a new one.
4.5.2 Harness AFL/AFL Main
Board P47)
4
The Main Unit Main Board
failure.
—
—
Replace the Main Board with
a new one.
Summary of Contents for PERFECTION V10
Page 7: ...C H A P T E R 1 PRODUCTDESCRIPTION ...
Page 17: ...C H A P T E R 2 OPERATINGPRINCIPLES ...
Page 26: ...C H A P T E R 3 TROUBLESHOOTING ...
Page 30: ...C H A P T E R 4 DISASSEMBLY ASSEMBLY ...
Page 56: ...C H A P T E R 5 ADJUSTMENT ...
Page 58: ...C H A P T E R 6 MAINTENANCE ...
Page 61: ...C H A P T E R 7 APPENDIX ...
Page 66: ...Model GT S600 Perfection V10 Board Main Board Rev C Sheet 1 1 ...
Page 67: ...Model GT F650 GT F700 Perfection V100 Photo V350 Photo Board Main Board Rev F Sheet 1 1 ...
Page 68: ...Model GT F670 Perfection V200 Photo Board Main Board Rev C Sheet 1 1 ...
Page 69: ...Model GT S600 GT F650 Perfection V10 V100 Photo Board CCD Board Rev D Sheet 1 1 ...
Page 70: ...Model GT F700 Perfection V350 Photo Board CCD Board Rev D Sheet 1 1 ...
Page 71: ...Model GT F670 Perfection V200 Photo Board CCD Board Rev A Sheet 1 1 ...
Page 73: ...Model GT F700 Perfection V350 Photo Board AFL Main Board Rev C Sheet 1 1 ...
Page 74: ...Model GT F700 Perfection V350 Photo Board AFL Sensor B Rev B Sheet 1 1 ...
Page 75: ...Model GT F700 Perfection V350 Photo Board AFL Sensor A Rev B Sheet 1 1 ...
Page 76: ...Model GT F670 Perfection V200 Photo Board Panel Board Rev B Sheet 1 1 ...