Appendix D Philips GP Quick Reference
Appendix D Philips GP Quick Reference
D-17
D-18
Table 7 (Cont.): Graphics Modes
Table 8: Barcode Printing
(for detail information see Appendix G)
Escape Sequence
Mnemonic Function
Escape Sequence
Mnemonic Function
ESC [ P1 h
SM
Set Mode Dot Graphics
P1 = graphics resolution
P1 = 2 5: 72x60 dpi dot format (VxH)
BH
Barcode Header
P1 = 2 6: 72x72 dpi dot format (VxH)
P2 :
Barcode typ
P1 = 2 7: 144x120 dpi dot format (VxH)
P3 :
Height of barcode
P1 = 2 8: 144x144 dpi dot format (VxH)
P4 :
Width of the thin bars
ESC [ P1
RM
Reset Mode Dot Graphics
P6 :
Ratio width to thin
P1 = graphics resolution
P7 :
Uni-directional or bidirectional
P1 = 2 5: 72x60 dpi dot format (VxH)
printing
P1 = 2 6: 72x72 dpi dot format (VxH)
P7 = 0 :
or not programmed: means no
P1 = 2 7: 144x120 dpi dot format (VxH)
changes
P1 = 2 8: 144x144 dpi dot format (VxH)
P7 = 1 :
uni-directional printing in LQ
ESC [ ; P2 ; P3 ; P4 ; P5 ; P6 ; P7
SP
z
P5 :
Width of the thin gaps
P7 = 2 :
bi-directional printing in LQ
P7 = 3 :
uni-directional printing in NLQ
P7 = 4 :
bi-directional printing in NLQ
Note:
A switch from uni-directional to bi-
directional printing is only possible if the
parameter
UNI-DIRECT.CMD
is set to
YES
via operator panel or ESC-sequence.
ESC [ ? 0 h
SMBC
Set Mode Barcode
ESC [ ? 0
RMBC
Reset Mode Barcode