![Epever TRIRON N Series User Manual Download Page 40](http://html1.mh-extra.com/html/epever/triron-n-series/triron-n-series_user-manual_2417340040.webp)
34
2
)
DS2 module display and operation
Operation:
Step1:
Press the
button for the setting interface.
Step2:
Press the
button and hold 5s for the load working mode interface.
Step3:
Press the
or
button to set the load working modes.
Step4:
Press the
button to confirm the parameters.
3
)
Load working mode
1**
Timer 1
2**
Timer 2
100
Light ON/OFF
2 n
Disabled
101
Load will be on for 1 hour since
sunset
201
Load will be on for 1 hour before
sunrise
102
Load will be on for 2 hours since
sunset
202
Load will be on for 2 hours before
sunrise
103
~
113
Load will be on for 3
~
13 hours
since sunset
203
~
213
Load will be on for 3
~
13 hours
before sunrise
114
Load will be on for 14 hours
since sunset
214
Load will be on for 14 hours
before sunrise
115
Load will be on for 15 hours
since sunset
215
Load will be on for 15 hours
before sunrise
116
Test mode
2 n
Disabled
117
Manual mode(Default load ON)
2 n
Disabled
NOTE: Please set Light ON/OFF, Test mode and Manual mode via
Timer1. Timer2 will be disabled and display "2 n ".
5.2.2 R485 communication setting
1
)
Load working mode
Manual Control (default)
Control ON/OFF of the load via the button or remote commands (e.g., APP or PC
software).
Summary of Contents for TRIRON N Series
Page 2: ......
Page 4: ......
Page 12: ...6 1 4 Designations of Controller Models EXAMPLE...
Page 14: ...8...
Page 22: ...16 3 Install the modules...
Page 23: ...17...
Page 55: ...49 Annex II Dimensions TRIRON1206N TRIRON1210N Unit mm...
Page 56: ...50 TRIRON2206N TRIRON2210N Unit mm...
Page 57: ...51 TRIRON3210N Unit mm...
Page 58: ...52 TRIRON4210N TRIRON4215N Unit mm Any changes without prior notice Version number 1 2...
Page 59: ......