![Epever TRIRON N Series User Manual Download Page 17](http://html1.mh-extra.com/html/epever/triron-n-series/triron-n-series_user-manual_2417340017.webp)
11
(2) Maximum PV array power
This MPPT controller has a limiting function of charging current/power. The charging
current/power will be limited within the rated range, therefore, the controller will
charge the battery with the rated charging power even if the input power at the PV
exceeds this limit.
The actual operation power of the PV array conforms to the conditions below:
1)
PV array actual power ≤ controller rated charge power, the controller will charge
the battery at the actual maximum power point.
2)
PV array actual power > controller rated charge power, the controller will charge
the battery at the charger
’s maximum rated power.
If the PV power is higher than the charger
’s maximum rated power, the charging time
at rated power to the battery will be longer, and more energy to battery will be stored
in the battery..
WARNING:
The controller has a maximum PV power input rating(watts), and will allow
the PV power to be higher than the rated power, but if the PV power is three
times greater than the rated power, the controller will damaged.
WARNING
:
If the PV array is reverse connected to the controller,1.5 times rated
power(watts) will damage the controller.
When sizing a PV array to a charge controller, be sure to choose PV panels that when
combined(or singly),will not exceed the controller
’s maximum inpt current rating(Isc)
and open circuit voltage rating(Voc), in addition to the power limitation noted above!
Please refer to the table below:
Model
Rated Charge
Current
Rated Charge
Power
Max. PV Array
Power
Max. PV open
circuit voltage
TRIRON1206N
10A
130W/12V
260W/24V
390W/12V
780W/24V
46V
①
60V
②
TRIRON2206N
20A
260W/12V
520W/24V
780W/12V
1560W/24V
TRIRON1210N
10A
130W/12V
260W/24V
390W/12V
780W/24V
92V
①
100V
②
TRIRON2210N
20A
260W/12V
520W/24V
780W/12V
1560W/24V
TRIRON3210N
30A
390W/12V
780W/24V
1170W/12V
2340W/24V
TRIRON4210N
40A
520W/12V
1040W/24V
1560W/12V
3120W/24V
TRIRON4215N
40A
520W/12V
1040W/24V
1560W/12V
3120W/24V
138V
①
150V
②
①
At 25
℃
environment temperature
②
At minimum operating environment temperature
Summary of Contents for TRIRON N Series
Page 2: ......
Page 4: ......
Page 12: ...6 1 4 Designations of Controller Models EXAMPLE...
Page 14: ...8...
Page 22: ...16 3 Install the modules...
Page 23: ...17...
Page 55: ...49 Annex II Dimensions TRIRON1206N TRIRON1210N Unit mm...
Page 56: ...50 TRIRON2206N TRIRON2210N Unit mm...
Page 57: ...51 TRIRON3210N Unit mm...
Page 58: ...52 TRIRON4210N TRIRON4215N Unit mm Any changes without prior notice Version number 1 2...
Page 59: ......