![Epever TRIRON N Series User Manual Download Page 18](http://html1.mh-extra.com/html/epever/triron-n-series/triron-n-series_user-manual_2417340018.webp)
12
WARNING
: The controller may be damaged when the maximum PV open
circuit voltage(Voc) exceeds 60V(TRIRON**06N), 100V(TRIRON**10N) or
150V (TRIRON**15N) at minimum operating environment temperature.
2.3 Wire Size
The wiring and installation methods must conform to all national and local electrical
code requirements.
PV Wire Size
Since PV array output can vary due to the PV module size, connection method or
sunlight angle, the minimum wire size can be calculated by the Isc
*
of PV array.
Please refer to the value of Isc in the PV module specification. When PV modules
connect in series, the Isc is equal to a PV modules Isc. When PV modules connect in
parallel, the Isc is equal to the sum of the PV module
’
s Isc. The Isc of the PV array
must not exceed the controller
’
s maximum PV input current. Please refer to the table
as below:
NOTE: All PV modules in a given array are assumed to be identical.
*
Isc=short circuit current(amps) Voc=open circuit voltage.
Model
Max. PV input current
Max. PV wire size
*
TRIRON1206N
TRIRON1210N
10A
4mm
2
/12AWG
TRIRON2206N
TRIRON2210N
20A
6mm
2
/10AWG
TRIRON3210N
30A
10mm
2
/8AWG
TRIRON4210N
TRIRON4215N
40A
16mm
2
/6AWG
*
These are the maximum wire sizes that will fit the controller terminals.
NOTE:
When the PV modules connect in series, the open circuit voltage of
the PV array must not exceed 46V (TRIRON**06N), 92V (TRIRON**10N)
or 92V (TRIRON**15N) at 25
℃
environment temperature.
Battery and Load Wire Size
The battery and load wire size must conform to the rated current, the reference size
as below:
Model
Rated
charge
current
Rated
discharge
current
Battery wire
size
Load wire
size
TRIRON1206N
TRIRON1210N
10A
10A
4mm
2
/12AWG
4mm
2
/12AWG
TRIRON2206N
TRIRON2210N
20A
20A
6mm
2
/10AWG
6mm
2
/10AWG
TRIRON3210N
30A
30A
10mm
2
/8AWG
10mm
2
/8AWG
TRIRON4210N
TRIRON4215N
40A
40A
16mm
2
/6AWG
16mm
2
/6AWG
Summary of Contents for TRIRON N Series
Page 2: ......
Page 4: ......
Page 12: ...6 1 4 Designations of Controller Models EXAMPLE...
Page 14: ...8...
Page 22: ...16 3 Install the modules...
Page 23: ...17...
Page 55: ...49 Annex II Dimensions TRIRON1206N TRIRON1210N Unit mm...
Page 56: ...50 TRIRON2206N TRIRON2210N Unit mm...
Page 57: ...51 TRIRON3210N Unit mm...
Page 58: ...52 TRIRON4210N TRIRON4215N Unit mm Any changes without prior notice Version number 1 2...
Page 59: ......