44
AGC_CTL: The data for adjusting the AGC level of the camera.
Data value range from 0x1C (Minimum AGC Level) to 0xDC
(Maximum AGC Level).
Caution: This command is valid when the Exposure Mode is “AGC MAN” or
“MANUAL”.
Function OSD Display Mode Change
Change the Function OSD Display Mode of the camera according to the
data of “OSD_DISP”.
PC
→
Camera
0xC5 0xAA 0x64 OSD_DISP CAM_ID C.S.
Camera
→
PC
0xC5 0xAA 0x64 OSD_DISP 0x64 0xXX 0xXX 0xXX C.S.
OSD_DISP
Bit
Explanation
7
Reserved, Fix to “0”.
6
Reserved, Fix to “0”.
5
0: OFF
1: General Function OSD Display ON (Focus Auto/Manual OSD, Back
Light OSD, Shutter Speed OSD, White Balance Mode OSD)
4
Reserved, Fix to “0”.
3
0: OFF.
1: Camera ID OSD Display ON.
2
0: OFF.
1: Zoom Magnitude OSD Display ON.
1
0: OFF.
1: User Title OSD Display ON.
0
0: OFF.
1: Power ON Initial Title OSD Display ON.
Digital Zoom Mode ON/ OFF Setting
Switch the Digital Zoom mode to ON or OFF according to the data of “MODE”.
PC
→
Camera
0xC5 0xAA 0x6E MODE CAM_ID C.S.
Camera
→
PC
0xC5 0xAA 0x6E MODE 0x6E 0xXX 0xXX 0xXX C.S.
1.
In case of MODE = 0x01, the Digital Zoom Mode is changed to “ON” mode.
2.
In case of MODE = 0x00, the Digital Zoom Mode is changed to “OFF” mode.
3.
Otherwise, the Digital Zoom Mode remains unchanged.
Summary of Contents for EFFIO-P
Page 65: ...64 MEMO...