68
246
EB. DRIV.OPEN
The EB coil driver is not able to
drive the load. The device itself or
its driving circuit is damaged.
This type of fault is not related to
external components. Replace the
logic board.
247
DATA
ACQUISITION
Controller in calibration state.
The alarm ends when the
acquisition is done.
248
NO CAN MSG.
CANbus communication does not
work properly. The hexadecimal
value “XX” identifies the faulty node.
1- Verify the CANbus network
(external issue).
2- Replace the logic board
(internal issue).
249
CHECK UP
NEEDED
This is a warning to point out that it
is time for the programmed
maintenance.
Turn on the CHECK UP DONE
option after that the maintenance
service.
Error Message
Possible cause
Fault elimination
Error
Error text
250
THERMIC SENS.
KO
The output of the controller
thermal sensor is out of range.
This kind of fault is not related to
external components. Replace the
controller.