52
147
NO CAN BMS EP
if the communication between BMS
and controller is out of time,this
alarm occurs
1-check the communication wiring
between BMS and controller
2-there's a fault on BMS can
device,repalce the BMS
148
EP BMS MC
OPEN
if the battery charge level is to
low,the BMS require the main
contactor open,this alarm occurs
1-check the battery charge level
2-check if the battery is ok
3-replace the BMS
149
EP BMS TRAC
CTB
if the battery charge level is to
low,the BMS require the controller
to reduce the traction speed,this
alarm occurs
1-check the battery charge level
2-check if the battery is ok
3-replace the BMS
150
EP BMS LIFT
STOP
if the battery charge level is to
low,the BMS require the controller
to stop the lift function,this alarm
occurs
1-check the battery charge level
2-check if the battery is ok
3-replace the BMS
151
EP BMS TRAC
STOP
if the battery charge level is to
low,the BMS require the controller
to stop the traction function,this
alarm occurs
1-check the battery charge level
2-check if the battery is ok
3-replace the BMS
153
OFFSET
SPD.SENS.
It is necessary to acquire the offset
angle between the stator and the
speed sensor, i.e. they mutual
angular misalignment. An automatic
function is dedicated to this
procedure.
Perform the teaching procedure: in
OPTIONS, select ABS SENS.
ACQUIRE.
155
WAIT MOTOR
STILL
The controller is waiting for the
motor to stop rotating. This warning
can only appear in controllers for
brushless motors
——
Error Message
Possible cause
Fault elimination
Error
Error text