53
161
RPM HIGH
This alarm occurs in Gen. Set
versions when the speed exceeds
the threshold speed.
——
170
WRONG KEY
VOLT.
The measured key voltage is not
the right one for the inverter.
1- Check if the SET KEY
VOLTAGE parameter in the
ADJUSTMENTS list
is set in accordance with the key
voltage.
2- Check if the key voltage is ok
using a voltmeter, if not check the
wiring.
3- In case the problem is not
solved, replace the logic board.
177
COIL SHOR.
EB.
This alarm occurs when an
overload of the EB driver occurs.
1- Check the connections between
the controller outputs and the
loads.
2- Collect information about
characteristics of the coil
connected to the
driver and ask for assistance to a
EP technician in order to verify that
the maximum current that can be
supplied by the hardware is not
exceeded.
3- In case no failures/problems
have been found, the problem is in
the controller, which has to be
replaced.