ON DEMAND SENSOR
Sensor is set 5 seconds after user stops pressing
button to set program number
SENSOR
ACTIVATION
RANGE
INTELLIGENT
AFTERFLOW
SENSOR
SENSITIVITY
LEVEL *
MAX FLOW
TIME
LOCK OUT
TIME
AFTER OFF
Number
of presses
PROGRAM DESCRIPTION
1
Automatic off - On Demand Sensor
active with 8 second runtime
Sensor range 20-100mm
20-100mm
4s +/- 1s
1
8 sec
0 sec
2
Default setting
Automatic off - On Demand Sensor
active with 15 second runtime
Sensor range 20-100mm
20-100mm
4s +/- 1s
1
15 sec
0 sec
3
Automatic off - On Demand Sensor
active with 30 second runtime
Sensor range 20-100mm
20-100mm
4s +/- 1s
1
30 sec
0 sec
4
Automatic off - On Demand Sensor
active with 45 second runtime
Sensor range 20-100mm
20-100mm
4s +/- 1s
1
45 sec
0 sec
5
Automatic off - On Demand Sensor
active with 60 second runtime
Sensor range 20-100mm
20-100mm
4s +/- 1s
1
60 sec
0 sec
6
Automatic off - On Demand Sensor
active with 120 second runtime
Sensor range 20-100mm
20-100mm
4s +/- 1s
1
120 sec
0 sec
7
Automatic off - On Demand Sensor
active with 180 second runtime
Sensor range 20-100mm
20-100mm
4s +/- 1s
1
180 sec
0 sec
8
Automatic off - On Demand Sensor
active with 15 second runtime
Sensor range 20-100mm
15 second lock out time after off
20-100mm
4s +/- 1s
1
15 sec
15 sec
9
Automatic off - On Demand Sensor
active with 30 second runtime
Sensor range 20-100mm
15 second lock out time after off
20-100mm
4s +/- 1s
1
30 sec
15 sec
10
Automatic off - On Demand Sensor
active with 45 second runtime
Sensor range 20-100mm
15 second lock out time after off
20-100mm
4s +/- 1s
1
45 sec
15 sec
11
Automatic off - On Demand Sensor
active with 60 second runtime
Sensor range 20-100mm
15 second lock out time after off
20-100mm
4s +/- 1s
1
60 sec
15 sec
12
Automatic off - On Demand Sensor
active with 120 second runtime
Sensor range 20-100mm
15 second lock out time after off
20-100mm
4s +/- 1s
1
120 sec
15 sec
13
Automatic off - On Demand Sensor
active with 180 second runtime
Sensor range 20-100mm
15 second lock out time after off
20-100mm
4s +/- 1s
1
180 sec
15 sec
14
Nurse mode A
10 sec ON 30 sec OFF 20 sec ON
20-100mm
15
Default setting
Automatic Flow OFF
Approx 1 minute
–
–
–
–
–
16
Automatic Flow 12h ON
–
–
–
–
–
PROGRAMMING
ON DEMAND SENSOR