www.enware.com.au
Call 1300 369 273
29
AUTO SENSE
PROGRAMMING
AUTO SENSE
Sensor is set 5 seconds after user stops pressing
button to set program number
SENSOR
ACTIVATION
RANGE
INTELLIGENT
AFTERFLOW
SENSOR
SENSITIVITY
LEVEL *
MAX FLOW
TIME
AUTOFLOW
INTERVAL
Number
of presses
PROGRAM DESCRIPTION
1
Automatic on - sensor range max.
170mm - standard afterflow.
20-170mm
2S +/- 1s
1
2 mins
2
Default setting
Automatic on - sensor range max.
250mm - standard afterflow
250mm spout setting
20-250mm
2S +/- 1s
1
2 mins
3
Automatic on - sensor range max.
170mm (4s +/- 1) second afterflow
Sensitivity level 2*
20-170mm
4S +/- 1s
2
2 mins
4
Automatic on - sensor range max.
250mm (4s +/- 1) second afterflow
Sensitivity level 2*
20-250mm
4S +/- 1s
2
2 mins
5
Automatic on - sensor range max.
170mm (4s +/- 1) second afterflow
Sensitivity level 3*
20-170mm
4S +/- 1s
3
2 mins
6
Automatic on - sensor range max.
250mm (4s +/- 1) second afterflow
Sensitivity level 3*
20-250mm
4S +/- 1s
3
2 mins
7
Default setting
Automatic flow OFF
Flush - Approx 1 minute
–
–
–
OFF
Factory setting
8
Automatic flow 12h ON
–
–
–
12H
*
SENSITIVITY LEVEL
1
Most sensitive
2
Less sensitive for difficult
light conditions or
interference
3 Least sensitive for
the most difficult light
conditions or interference