FITTING THE FACE PLATE
STEP 9
Remove the spout from spout retainer.
STEP 10
Connect the cables on the sensor to the solenoid
and the battery making sure the lines on the two
connectors align. SEE IMAGE 17
For 12V mains powered installations, the
transformer lead MUST connect to the cable
marked 12V, leaving the other cable to the
solenoid. Cross connection here will damage
the sensor and void the product warranty.
SEE IMAGE 18
STEP 11
Activate the sensor by placing your hand in front
of sensor about 10cm away for 1 second for On
Demand Sensor models, or by holding your hand
in front of sensor for Auto Sense models. Listen for
the solenoid to click open.
(Water is still off due to the cartridge position
in Step 8). SEE IMAGE 19
NOTE: Do not high pressure test the supply
system, as this may damage the thermostatic
cartridge (Max 1000KPa).
STEP 12
Take the chrome faceplate, carefully push the plate
over the spout retainer, then place its 2x lower
tabs into the 2x voids in the base of the faceplate
bracket until it sits flush.
Secure in place using the 2x M4 Allen head screws
and tighten with an Allen key. SEE IMAGE 20 and 21
IMAGE 17
IMAGE 20
IMAGE 19
IMAGE 21
INSTALLATION PROCEDURE
FRONT OF WALL
IMAGE 18