D4K Pro® User Manual
D4K_UserManual_v1.3_EN.docx, 2021-02-12
Page 13 of 52
4
Technical Data
4.1
Mechanical Data
D4K®
Printing Area (mm)
148 x 83.4 x 120
W x D x H (cm)
50 x 57 x 59
XY Resolution
54.6 μm
Z-layer Resolution
5 μm to 200 μm
Wavelength (LED)
385 nm
UI & Connectivity
Touch screen / Ethernet, USB
Adapter: 100~240V AC, 1.5A, 50Hz/60Hz
4.2
Power Requirements
We strongly recommend you use
an uninterrupted power supply to protect your printer. All electrical requirements must be met to
ensure the most stable setup:
•
D4K Pro
– 19V DC / 4.73A
•
With
adapter
(included) – 100~240V AC, 1.5A, 50Hz/60Hz.
1. Plug the printer into a separate surge protector or battery backup.
2. If your electrical line is prone to spikes and dips, you will need to use a UPS battery backup system for the printer with
a switch changing time of less than 1 millisecond.
3. Do not plug any additional equipment into the power circuit.
4. Ensure there is a sufficient clean electrical socket that fluctuates no more than +/-3% (EU: +/-5%) from its baseline.
WARNING!
Risk of injury! Risk of damage to the printer!
Failure to use the grounding devices may lead to damage or injuries!
Connect ground wire before using!
Only use the grounding adapters of the plug & socket type targeted for the country of intended use of the printer!
Grounding of electrical receptacles is an important safety feature that minimizes the risk of electric shock and protects electrical
equipment from damage. For proper operation and in order not to disrupt the operation of the printer, ground the printer before
start working with it!
Figure 1: Grounded plug and outlet for Europe / Grounded plug and outlet for the US
4.3
Network Requirements
•
139, 445 ports
: are used to access the shared network folder (job, logs, update) on the printer. Also, they are used to
upload jobs to the printer via network.
•
5900 port
: VNC server for printer remote control (see
Connect to the Printer via VNC Clients
)
•
2504
port
: is used for connection between the D4K Control Software and Envision One RP.
•
22 (ssh)
and
443 (https)
:
are used for getting the software update.