AFTER INSTALLING THIS UNIT PLEASE PASS ONTO END USER
DO NOT THROW AWAY
26
Setting the air flow rate
The factory supplies the units with the
energiSava 300 flow rates set to 50, 100, 150
and 225 m
3
/h and for the energiSava 400 set
to 50, 100, 200 and 300 m
3
/h respectively. The
performance and the energy consumption of
the units depend on the pressure drop in the
duct system as well as on the filter resistance.
Important:
Mode : is 0 or 50 m
3
/h (not in combination with
a 3-way switch).
• Mode 1: Must always be lower than mode 2.
• Mode 2: Must always be lower than mode 3;
• Mode 3:
energiSava 300 - adjustable between 50 and
300 m
3
/h;
energiSava 400 - adjustable between 50 and
400 m
3
/h;
If these conditions are not complied with, the air
flow rate of the higher mode will automatically
be adjusted.
See the settings menu, (see page 22), for
changing the flow rates.
Other settings
Various other settings for the units can also be
modified. How to modify these is explained is
on page 22.
Factory setting
It is possible to reset all modified settings back
to factory setting in one go.
All settings will be returned to the values
originally supplied with the unit from the
factory; all message codes / fault codes will be
erased from the service menu as well. The filter
notification process will not reset.
06
Operation
Press > 10 sec.
simultaneously
Operating mode
3 sec visible
Summary of Contents for energiSava 300
Page 1: ......
Page 40: ...SHOULD YOU ENCOUNTER ANY PROBLEMS INSTALLING THIS UNIT CALL 39 10 Servicing...