SHOULD YOU ENCOUNTER ANY PROBLEMS INSTALLING THIS UNIT CALL
45
12
ErP
Product data sheet conform Ecodesign (EU), nr. 1254/2014 (Annex IV)
Supplier:
EnviroVent
Model:
energiSava 400
Climate zone
Type of control
SEC-Value
in kWh/m²/a
Energy class (SEC)
The annual electricity
consumption (AEC)
in kWh
The annual heating
saved (AHS)
in kWh
Average
Manual
-36,26
A
346
4371
Clock
-37,23
A
331
4395
1 Sensor (RH/CO2/VOC)
-39,06
A
301
4442
2 or more Sensors (RH/CO
2
/VOC)
-42,27
A+
240
4536
Cold
Manual
-78,55
A+
883
6672
Clock
-79,75
A+
868
6708
1 Sensor (RH/CO2/VOC)
-82,04
A+
838
6780
2 or more Sensors (RH/CO2/VOC)
-86,16
A+
777
6924
Warm
Manual
-12,03
F
301
2301
Clock
-12,87
E
286
2313
1 Sensor (RH/CO2/VOC)
-14,44
E
256
2338
2 or more Sensors (RH/CO2/VOC)
-17,13
E
195
2388
Type of ventilation unit:
Ventilation unit with heat recovery
Fan:
Variable speed EC fan
Type of heat exchanger:
Recuperative plastic cross-counterflow heat exchanger
Thermal efficiency:
85%
Maximum flow rate:
400 m³/h
Electric power input:
142 W
Sound power level Lwa:
48 dB(A)
Reference flow rate :
280 m³/h
Reference pressure difference:
50Pa
Specific Power Input (SEL):
0,24 W/m³/h
Control factor:
1,0 in combination with manual switch
0,95 in combination with clock
0,85 in combination with 1 sensor
0,65 in combination with 2 or more sensors
Leakage*:
Internal
0,4%
External
1,3%
Filter warning:
On the display of the ventilation unit / Manual switch / clock control.
Attention! For optimal energy efficiency and a proper operation a regular filter
inspection, cleaning or replacement is necessary.
Internet address for Assembly instructions:
www.envirovent.com
Bypass:
Yes; 100% Bypass
*Measurements executed by TNO according to the EN 13141-7 standard (TNO-report TNO 2013 M10230, February 2013)