25
7.2.5 Sensor
Selection:
The Evaluation unit verifies the availability
SolidFlow 2.0 / PicoFlow / of registered sensors on the selected
ProSens / SpeedFlow 2.0 / type, calculates the measurement values
Paddy / MaxxFlow HTC /
on this basis and signals if necessary
DensFlow / SlideControl /
corresponding errors.
M-Sens 2 / M-Sens 3 /
Incorrect sensor selection leads to a refusal
M-Sens WR3, AirFlow P
to communicate.
7.3. Display
Submenu
7.3.1 Sensor info
Selection:
ON:
Show info key on display
ON / OFF
OFF:
Hide info key
7.3.2 Process indicator
Selection:
ON:
Process indicators will be shown on
ON / OFF
display and via double blink on the DIN Rail.
OFF:
Process indicators will not be shown.
7.3.3 Backlight
Input:
0 … 99 min
Lighting of the Display in minutes
0 = permanent lighting
99 = time selection for lighting
7.3.4 Contrast
Input:
0 … 100 %
In the case of display exchange, the contrast
can be changed via the PC software, if
necessary.
7.4 Address
Input:
1 … 255
ModBus address of Evaluation unit, if operated
on a PLC or PC as a slave.
7.5
Baud rate
Selection:
Communication speed of the Evaluation
4800/9600/19200/
unit when this is operated as a ModBus
38400 baud
slave on a PLC or a PC.
7.6 Parity
Selection:
The parity is set to even by default.
EVEN/ODD/NONE
The parity is important for further
communication. A change of the parity is
only valid after a restart of the power
supply.
7.7
Password
Input:
0 … 9999
0000 = No password
XXXX = Four-digit password, which is
queried when the menu is called up on
the display. Automatic lock five minutes
after the last display input.
7.8
Init Screen
Selection:
If ticked, after power OFF, MSE 300-FH
will restart on initialization screen.