Section 4 – Quick Start
46 |
P a g e
4.10
Access the Electrode menu
Discrete I/O
Bus I/O
Analog I/O
System
0
Configure
˅
Electrode
History Log
Use Program
˄
Program
i
Main Menu
4.10.1.
Access the Current Calibration screen
˅
Counter
Stepper
Current cal. Force cal.
˄
i
Electrode menu
4.10.1.1. Set the current calibration parameters
Set the parameters as shown:
Toroid
150 mV/kA
CT
1950 mV/kA
Point 1 (Sec)
1.00 kA
Point 2 (Sec)
10.0 kA
˄
˅
1:1
Off
Point 1 (Pri)
200 A
Point 2 (Pri)
500 A
Power Factor
0.30
Turns Ratio
Apply Conversion
i
Calibrate Current: Electrode 0
4.11
We’re ready to weld!