Section 3 – Menus
33 |
P a g e
3.5.16.
I/O source
Select the I/O source
Discrete – use the discrete terminals X2 and X3.
COM0 – use MODBUS TCP/IP (Ethernet) on COM0
COM1 – use MODBUS TCP/IP (Ethernet) on COM1.
COM2 – use MODBUS RTU (RS485) on COM2.
COM3 – use RS232 on COM3.
COM4 – use MODBUS TCP/IP (Ethernet) on COM4.
COM5 – use MODBUS TCP/IP (Ethernet) on COM5
COM6 (E/IP) – use EtherNet/IP on COM6.
3.5.17.
Analog output
Select
Force Control
or
Analog Waveform
3.5.18.
Waveform 10V=
The full-scale value of current that corresponds to 10 Vdc on the
Analog output channel.
Analog Output
must be set to
Analog
Waveform
to use this function.
3.5.19.
Contactor
The time that the Isolation Contactor (if equipped) is to remain on
after the last weld (delay off).
3.5.20.
Clock menu
Tap this button to open the clock menu and set the current time and
date.
3.5.21.
COM0
Tap to view the COM0 information.
3.5.22.
COM1
Tap to view the COM1 information.