3.2.8. Options menu
Program
Inhibit
Pre‐heat
˄
Repeat
Force profile
˅
Link
Pulsations
3
Post‐heat
i
Options: Program 0
3.2.8.1. Program Inhibit (parameter)
Checking this box will prevent a program from executing. If the
program is not linked, attempting to run it will produce an error
message. If the program is linked, it will be skipped and the next
linked program will run.
3.2.8.2. Pre-heat (parameter)
Checking this box will enable the Pre-heat parameters.
3.2.8.3. Post-heat (parameter)
Check this box to enable Post-heat features.
3.2.8.4. Pulsations (parameter)
This value is the number of times the Main Heat – Cool 2 interval is
repeated.
3.2.8.5. Link (parameter)
Check this box to enable linking. The linked program selected in
the Program menu will begin automatically if the START signal is
maintained. Linking cannot be used if
Repeat
is selected.
3.2.8.6. Repeat (parameter)
Checking this box will set repeat mode in the program. It is
available in Spot weld mode only, as set in the
Configuration
menu.
Repeat
cannot be used if
Linking
is selected.