Section 3 – Menus
10 |
P a g e
3.2.4. Timing menu
50 ~
Hold
Pre‐heat
˄
10 ~
20 ~
Squeeze
Upslope
2 ~
Cool 2
˅
Downslope
2 ~
20 ~
Post‐heat
20 ~
Cool 1
2 ~
Main Heat
30 ~
i
Timing: Program 0
3.2.4.1. Presqueeze (parameter)
Time interval between program initiation and the start of squeeze
time. Only occurs on the first spot of a
Repeat mode
spot
sequence. Used to allow for large initial movements of the welding
electrodes.
3.2.4.2. Squeeze (parameter)
Time interval between end of
Presqueeze
time and the application
of weld current. Used to allow the electrodes to develop the desired
force.
3.2.4.3. Pre-heat (parameter)
Time interval where the Pre-heat current is applied.
Pre-heat
must
be enabled in the
Program Options
menu.
3.2.4.4. Cool1 (parameter)
Time interval between end of
Pre-heat
time and start of
Upslope
time where no current is passed. Pre-heat must be enabled in the
Program Options
menu to use this feature.
3.2.4.5. Upslope (parameter)
Time interval for the welding current to change from the Pre-heat
value to the Main Heat value.