Section 3 – Menus
31 |
P a g e
3.5.1. Features
Sets
Extended
or
Standard
features. Set to
Extended
to enable the
following features:
Seam welding
Post-heat interval
Force profile
Multi electrodes
Cascade
Multi WAV.
If the application does not need these features, select
Standard
to reduce
the number of menu items displayed. The EN7000 must be restarted after
changing this setting.
3.5.2. Weld type
Select
Spot
/
Seam
. The EN7000 must be restarted after changing this
setting
3.5.3. Sensor
Select
CT
or
Toroid
for the type of sensor connected to the control for
current measurement. Normally, a CT is used on the primary and a Toroid
is used on the secondary.
3.5.4. Toroid test
If set to
ON
, the EN7000 will test the resistance of the external toroid to be
within a range of 10 – 300 Ohms.
3.5.5. Frequency (parameter)
Set to
50 Hz
or
60 Hz
to match the frequency of the AC line.
3.5.6. Units (parameter)
Select
METRIC
/
IMPERIAL
3.5.7. Program select (parameter)
Set the source for Program selection. Select
EXTERN
for discrete input or
field bus. Select
INTERN
to use the program number entered in the
Use
program
parameter.
3.5.8. Electrodes
Select
Single
for one electrode or
Multi
for up to eight.
Extended
Extended