36
IP1861EN - 2015-12-02
11. Limit switch adjustment (QIK4E only)
- Adjust the opening and closing position of the bar using the special screws [A].
- Adjust the opening and closing limit switches using the special cams [C] so that the switches
are activated approx. 3 mm before the mechanical stop [B].
Before connecting the power supply, make sure the plate data correspond to that of the
mains power supply.
An omnipolar disconnection switch with minimum contact gaps of 3 mm must be included in
the mains supply.
Check that upstream of the electrical installation there is an adequate residual current circuit
breaker and a suitable overcurrent cutout.
Use a H05RN-F 3G1.5 or H05RR-F 3G1.5 type electric cable and connect it to terminals L (brown)
and N (blue) inside the automation.
Connect the earth wire
.
Connection to the mains power supply, in the section outside the automation, is made with
independent channel and separated from the connections to the control and safety devices.
The channel must penetrate the automation through the holes on the base plate at least 50 mm.
Make sure there are no sharp edges that may damage the power supply cable.
Make sure the mains power conductors (230 V) and accessory power conductors (24 V) are
separated.
12. Electrical
connections
N.B.: The electrical wiring and start-up of the gearmotors are shown in the control panel installation manuals.
i
A
A
B
C
C
QIK4E
QIK7EH - QIK7YEH
Control panel
E1A
EL31R
Summary of Contents for Ditec QIK4E
Page 1: ...Ditec QIK4E 7EH 7YEH www ditecentrematic com IP1861 2015 12 02 ...
Page 2: ...2 IP1861 2015 12 02 Italiano 3 English 23 Français 43 Deutsch 63 Español 83 Português 103 ...
Page 4: ...4 IP1861IT 2015 12 02 ...
Page 10: ...10 IP1861IT 2015 12 02 5 Dimensioni 1050 575 125 840 300 210 50 40 320 PL min 1300 max 5800 ...
Page 18: ...18 IP1861IT 2015 12 02 ...
Page 24: ...24 IP1861EN 2015 12 02 ...
Page 30: ...30 IP1861EN 2015 12 02 5 Dimensions 1050 575 125 840 300 210 50 40 320 PL min 1300 max 5800 ...
Page 38: ...38 IP1861EN 2015 12 02 ...
Page 44: ...44 IP1861FR 2015 12 02 ...
Page 50: ...50 IP1861FR 2015 12 02 5 Dimensions 1050 575 125 840 300 210 50 40 320 PL min 1300 max 5800 ...
Page 58: ...58 IP1861FR 2015 12 02 ...
Page 64: ...64 IP1861DE 2015 12 02 ...
Page 70: ...70 IP1861DE 2015 12 02 5 Abmessungen 1050 575 125 840 300 210 50 40 320 PL min 1300 max 5800 ...
Page 78: ...78 IP1861DE 2015 12 02 ...
Page 84: ...84 IP1861ES 2015 12 02 ...
Page 90: ...90 IP1861ES 2015 12 02 5 Dimensiones 1050 575 125 840 300 210 50 40 320 PL min 1300 max 5800 ...
Page 98: ...98 IP1861ES 2015 12 02 ...
Page 104: ...104 IP1861PT 2015 12 02 ...
Page 110: ...110 IP1861PT 2015 12 02 5 Dimensões 1050 575 125 840 300 210 50 40 320 PL min 1300 max 5800 ...
Page 118: ...118 IP1861PT 2015 12 02 ...
Page 123: ...123 IP1861 2015 12 02 ...