![Entrematic Ditec QIK4E Manual Download Page 28](http://html.mh-extra.com/html/entrematic/ditec-qik4e/ditec-qik4e_manual_2415178028.webp)
28
IP1861EN - 2015-12-02
3. Technical specifications
QIK4E
QIK7EH-QIK7YEH
Power supply
230 V~ 50 Hz
230 V~ 50/60 Hz
Absorption
1,5 A
1 A
Line fuse
F1,6A
F1,6A
Torque
90 Nm
70 Nm
Insulation class
Class 1
Class 1
Opening time
4 s/90°
2÷6 s/90°
Closing time
4 s/90°
2÷6 s/90°
Bar length (max)
3700 mm
6000 mm
Service class
4 - INTENSE
5 - VERY INTENSE
Intermittence
S2 = 15 min
S3 = 30%
S2 = 60 min
S3 = 60%
Temperature
min -20° C max +55° C
min -20° C max +55° C
Degree of protection
IP24D
IP24D
Control panel
E1A
EL31R
3.1 Operating
instructions
Service class:
4 (minimum 10÷5 years of working life with 100÷200 cycles per day).
Applications:
INTENSE (for apartment block, industrial and commercial entrances and car parks
with vehicle access or access for intense pedestrian use).
Service class:
5 (minimum 5 years of working life with 600 cycles per day).
Applications:
VERY INTENSE (for apartment block, industrial and commercial entrances and
car parks with vehicle access or access for very intense pedestrian use).
- Performance characteristics are to be understood as referring to the recommended weight (ap-
prox. 2/3 of maximum permissible weight). When used with the maximum permissible weight
a reduction in the above mentioned performance can be expected.
- Service class, running times, and the number of consecutive cycles are to be taken as merely
indicative, having been statistically determined under average operating conditions, and are
therefore not necessarily applicable to specific conditions of use.
- Each automatic entrance has variable elements such as: friction, balancing and environmental
factors, all of which may substantially alter the performance characteristics of the automatic
entrance or curtail its working life or parts thereof (including the automatic devices themselves).
The installer should adopt suitable safety conditions for each particular installation.
i
Every automatic system contains variable elements (friction, balancing and environ-
mental factors) that may substantially alter both the lifespan and performance of the
system or its components (including the spring). Tests have shown that the average
spring lifespan is around 300.000 cycles, so you are advised to check its state of wear
when this limit is reached. If there are clear signs of wear, or it is difficult to balance
the bar correctly, replace the spring.
Summary of Contents for Ditec QIK4E
Page 1: ...Ditec QIK4E 7EH 7YEH www ditecentrematic com IP1861 2015 12 02 ...
Page 2: ...2 IP1861 2015 12 02 Italiano 3 English 23 Français 43 Deutsch 63 Español 83 Português 103 ...
Page 4: ...4 IP1861IT 2015 12 02 ...
Page 10: ...10 IP1861IT 2015 12 02 5 Dimensioni 1050 575 125 840 300 210 50 40 320 PL min 1300 max 5800 ...
Page 18: ...18 IP1861IT 2015 12 02 ...
Page 24: ...24 IP1861EN 2015 12 02 ...
Page 30: ...30 IP1861EN 2015 12 02 5 Dimensions 1050 575 125 840 300 210 50 40 320 PL min 1300 max 5800 ...
Page 38: ...38 IP1861EN 2015 12 02 ...
Page 44: ...44 IP1861FR 2015 12 02 ...
Page 50: ...50 IP1861FR 2015 12 02 5 Dimensions 1050 575 125 840 300 210 50 40 320 PL min 1300 max 5800 ...
Page 58: ...58 IP1861FR 2015 12 02 ...
Page 64: ...64 IP1861DE 2015 12 02 ...
Page 70: ...70 IP1861DE 2015 12 02 5 Abmessungen 1050 575 125 840 300 210 50 40 320 PL min 1300 max 5800 ...
Page 78: ...78 IP1861DE 2015 12 02 ...
Page 84: ...84 IP1861ES 2015 12 02 ...
Page 90: ...90 IP1861ES 2015 12 02 5 Dimensiones 1050 575 125 840 300 210 50 40 320 PL min 1300 max 5800 ...
Page 98: ...98 IP1861ES 2015 12 02 ...
Page 104: ...104 IP1861PT 2015 12 02 ...
Page 110: ...110 IP1861PT 2015 12 02 5 Dimensões 1050 575 125 840 300 210 50 40 320 PL min 1300 max 5800 ...
Page 118: ...118 IP1861PT 2015 12 02 ...
Page 123: ...123 IP1861 2015 12 02 ...