46
IP2159EN - 2017-06-12
20.3 Interlocked automations (DAB905SYN)
MASTER
DOOR A
DOOR B
SLAVE
MASTER
SLAVE
DOOR
B
MAGNET
SWITCH
DOOR
A
MAGNET
SWITCH
In applications for interlocked doors, a micro switch must be installed on the MASTER A automation in order to disable
opening of the MASTER B automation and vice versa.
When both doors are closed, the 3-GND 7-KILL contact is open. The first automation that opens closes the contact and
prevents the other automation from moving.
When the first automation has closed, the second automation can open by way of a second opening command.
NB: If a KILL command is given to the SLAVE automation, only the SLAVE door will stop.
NB: If single interlocked doors are installed, the same connections indicated above are used.