34
IP2159EN - 2017-06-12
Door wing weight [kg]
50
60
70
80
90
Door
w
ing
lengt
h
[mm]
750
3,0 s (3,0 s)
3,0 s (3,2 s)
3,0 s (3,2 s)
3,0 s (3,3 s)
3,5 s (3,5 s)
850
3,0 s (3,1 s)
3,0 s (3,1 s)
3,5 s (3,2 s)
3,5 s (3,4 s)
4,0 s (3,6 s)
1
000
3,5 s (3,2 s)
3,5 s (3,4 s)
4,0 s (3,7 s)
4,0 s (4,0 s)
4,5 s (4,2 s)
12
0
0
4,0 s (3,8 s)
4,5 s (4,2 s)
4,5 s (4,5 s)
5,0 s (4,8 s)
5,5 s (5,1 s)
The DAB105 automation is factory supplied with the Low Energy setting enabled. If necessary, adjust the OPSP and CLSP
trimmers so that the opening and closing times are the same or longer than those indicated in the table in accordance with
EN16005:2012 and ANSI 156.19 (the information in brackets refers to DIN 18650-2).
The table shows the minimum opening times for opening of up to 80° and the minimum closing times for openings from 90° to 10°.
15. Door requisites for Low Energy use
Or modify the classifications as shown in the table.
1. Disconnect the batteries (if installed).
2. Disconnect the mains power supply.
3. Press the LRN self-learning button, and keep it pressed. Enable the power supply.
4. The LED will light up
3s
3s
3s
.
5. Release the LRN self-learning button - the LED will switch off.
6. The LED flashes as many times as the classification number (see table).
7. Press the LRN button to pass to the next classification number after the set one.
8. Press the LRN button until you reach the required classification.
9. Disconnect the mains power supply.
10. When the mains power supply is reconnected, the automation will use the new setting.
CLASSIFICATION
1 - Maximum performance (Default)
2 - Low energy
Standard
/
In accordance with DIN18650-2 (EN16005:2012)
Opening speed
3-6 s
Automatic limit 1,69J
Closing speed
3-6 s
Automatic limit 1,69J
Launch the automatic self-learning procedure (LRN button) after every parameter setting modification.
i
The maximum setting for the opening speed and closing speed is automatically limited to the value indicated in the table; conse-
quently, the speed may only be reduced.