37
IP2159EN - 2017-06-12
Contact
Function - Accessory
Description
3
7
GND-KILL
NO
EMERGENCY CLOSURE
(FIRE BARRIERS)
The closure of the contact activates an emergency closure operation. This command is ac-
tive in every situation, and has priority over every other command.
When the contact has reopened (with JUMPER J=ON), the door resumes operating as set
by the selector.
WARNING: if an EMERGENCY CLOSURE is activated, all the safety functions are
ignored and the door closes. People or objects in the path of the door during the
closing operation could suffer serious injury or damage.
This function is generally used to cut off a specific area in the case of a fire.
NB: this command can be combined with an emergency button.
The output contact can be changed from NO to NC by altering the pre-configured param-
eters, as explained in chapter 13.
The operation of the block during the emergency closure can be selected from the pre-set
parameters explained in chapter 13.
A panic bar can be installed in combination with a magnetic block on the fire barrier.
In the event of a fire alarm or a power supply failure, the panic bar keeps the closed door
blocked. In the case of escape routes, the panic bar can be manually released.
Configure the relay contact of the DAB905ESA card, choosing parameter 11, 12 or 13 as
explained in chapter 13.
3
7
GND-KILL
NO
“NURSE & BED” FUNC-
TION
In installations with parallel doors, the “NURSE & BED” function can be enabled by con-
necting a switch to contacts 3-7 on the SLAVE door control panel.
With 3-7 closed, opening of the MASTER door is enabled (NURSE function).
With 3-7 open, opening of both doors is enabled (BED function).
3
7
GND-KILL
NO
INTERLOCKED DOORS
Applications with interlocked doors are possible. For the connections, see paragraph 21.1.
3
8
GND-JRST
NO
EMERGENCY
OPENING
If JUMPER=ON, the panel makes an automatic reset after an emergency closure.
3
9
GND-UNL
NO
DOOR RELEASED
SIGNAL
Contact for door released signal.
The closure of the contact brings forward the opening operation when the electric lock /
electric strike is fully released, within the time set by the delay time adjustment trimmer
(max. 3 s).
3
10
GND-OFF
NO
DOOR CLOSED
Contact for connecting a closed door timer.