MAIN MENU FLOW:
024.00
Only valid for
DCV-10C/10CS/
11C/11CS.
Only valid for
DCV-10A/11A.
Only valid for
DCV-10S/10CS/
11S/11CS.
RESET
DISPLYSET
LANGUAGE
tENG
FCTRY SET
SECURITY
ESCAPE
RS 485
PERIOD
001
ALARMS
ANLG OUT
NO
SET
Press for 3 s.
V
2.2.1 PERIOD Period Setting Menu
After the device samples for a specified time, it displays the measurement result by calculating the
mean value of those samples. You can set the sampling time in this menu. Period value can be entered
between 1-600 seconds.
PERIOD
PERIOD
PERIOD
01
PERIOD
SET
001
05
050
SET
SET
2.2.2 ALARMS Alarms Menu
DCV -10C/10CS/11C/11CS devices have two normally open (NO) contact outputs. Operating modes
of the alarms are set in this menu. Each alarm can be set to one of six operating modes. These modes
are high alarm, low alarm, high-low (range) alarm and their 3 inverted counterpart modes. This menu
has 4 sub-menus.
ALARM1, ALARM2, TRIP, LATCH.
ALARMS
SET
ALARM 1
SET
TRIP
ALARM 2
NO
LATCH
NO
BACK MENU