background image

 

EN109-1400912-4E IFU 

 

 Page 

4

 of 

22

 

2.

 

SYMBOLS 

 

Follow the instructions in the Instructions for Use. 
It is important that you read, understand, and observe the 
precautionary and operating instructions 

 

 

 

Indicates a hazardous situation which, if not avoided, could result in:  

a.

 

Death or serious injury to the patient or operator (or) 

b.

 

Minor to moderate injury to the patient or operator (or) 

c.

 

Damage to the equipment 

 

 

 

Temperature Range  
Indicates acceptable temperature range 

 

 

 

Humidity Limits 
Indicates acceptable relative humidity 

 

 

 

Atmospheric Pressure 
Indicates the range of atmospheric pressure to which the medical 
device can be safely exposed. 

 

 

 

Electric waste can be reused. 
Indicates the electrical and electronic components of the device that 
can be recycled and must be disposed of separately. 

 

 

 

Manufacturer name and address and production date 

 

 

 

Reference Number or Part Number 

 

 

 

Serial Number 
Indicates the 

manufacturer’s serial number so that a specific medical 

device can be identified. 

 

 

IP 44

 

Ingress Protection Marking, classifies and rates the degree of 
protection provided against intrusion (body parts such as hands and 
fingers), dust, accidental contact, and water by mechanical casings and 
electrical enclosures.

 

 

 

 

Double Insulation

 

 

 

 

Indicates manufacturer's declaration that the product meets the 
requirements of the applicable EC directives

 

 

 

 

Type B applied part complying with the specified requirements to 
provide protection against electric shock, particularly regarding 
allowable patient leakage current and patient auxiliary current. 

  

Summary of Contents for MANUMED

Page 1: ...INSTRUCTIONS FOR USE October 1st 2019 EN109 1400912 4E IFU MANUMED...

Page 2: ...INDEX 1 FOREWORD 3 2 SYMBOLS 4 3 INTENDED USE AND INTENDED USER 5 4 PACKAGE CONTENTS 5 5 INSTALLATION 5 6 PRECAUTIONS 6 7 OPERATION 8 8 SAFETY INSTRUCTIONS 14 9 MAINTENANCE 16 10 SPECIFICATIONS 18 11...

Page 3: ...opment and production of this couch a great deal of care was put into the reliability safety ease of use and durability It is important to read the following instructions carefully before using your M...

Page 4: ...Indicates the electrical and electronic components of the device that can be recycled and must be disposed of separately Manufacturer name and address and production date Reference Number or Part Numb...

Page 5: ...he manufacturer of this equipment is not permitted 5 INSTALLATION Take the Manumed and any extra parts out of the cardboard packaging and check everything for possible transport damage Read this manua...

Page 6: ...kg optional is allowed when the height of the couch is being adjusted If the couch is equipped with an electric motor never let the motor exceed 4 minutes continuous operation If this should happen a...

Page 7: ...orts are not suited to sit upon and must be used to support the arms only When adjusting this couch keep hands away from the couch for at least 20 cm especially on places that have been marked by the...

Page 8: ...a smooth surface The couch is not designed to move across thresholds ADJUSTMENT TO THE FLEXION POSITION Use one hand to unlock the couch section locks while setting the tops into position with the ot...

Page 9: ...hand to unlock the leg section lock while adjusting the section upward with the other hand Trendelenburg down pull 3 use one hand to unlock the leg section lock while adjusting the section downward w...

Page 10: ...section in the desired position Leg section pull the handle underneath the leg section and adjust the leg section in the desired position Use one hand to unlock the couch section lock while adjusting...

Page 11: ...to recall the programmed position B Reprogramming the positions of the back section and the sitting section a Adjust the sections to the desired position b Press keys 1 and 2 simultaneously c Confirm...

Page 12: ...orizontal position HEIGHT ADJUSTMENT WITH THE CIRCULAR SWITCH BAR By pressing the circular switch bar which is located underneath the framework up or down with your foot the required height of the cou...

Page 13: ...EN109 1400912 4E IFU Page 13 of 22 Changing the height of the circular switch bar...

Page 14: ...on combined with the lowest possible position a Underneath the head section between the head section and floor b Underneath the leg section between the leg section and framework c Under the couch adju...

Page 15: ...On this couch a warning sticker is placed When adjusting this couch keep hands away from the couch for at least 20 cm especially on places that have been marked by the hand crush warning symbol FIX RO...

Page 16: ...lean the couch as described above before proceeding to disinfect the couch Follow the disinfectant s instructions for use Never use a mixture of disinfectants or a disinfectant and soap mixture Prefer...

Page 17: ...ed for a long period EXPECTED SERVICE LIFETIME Provided the annual maintenance is carried out by a qualified Enraf Nonius service technician or by an official distributor as described in the service m...

Page 18: ...57 80 47 100 200 kg 2 0 A 213 Optimal 3 section x x 204 x 67 57 80 47 97 200 kg 243 Optimal 3 section x x 204 x 67 57 80 47 100 200 kg 2 0 A 214 Optimal 3 section x x 204 x 67 57 80 47 97 200 kg 224 O...

Page 19: ...6 96 200 kg 622 Comfort 3 section x 200 x 67 46 99 200 kg 2 0 A 632 Comfort 3 section x 200 x 67 46 99 200 kg 2 0 A 613 Comfort 3 section x x 200 x 67 46 96 200 kg 623 Comfort 3 section x x 200 x 67 4...

Page 20: ...3 42 EEC ORDERING INFORMATION For the ordering data of the Manumed standard accessories and additional accessories we refer to http www enraf nonius com ENVIRONMENT CONDITIONS Environment conditions f...

Page 21: ...liable for any indirect special incidental or consequential damages arising from the use of or inability to use the product including without limitation damages for loss of goodwill work and productiv...

Page 22: ...EN109 1400912 4E IFU Copyright Enraf Nonius B V Vareseweg 127 3047 AT Rotterdam The Netherlands Tel 31 0 10 20 30 600 info enraf nonius nl...

Reviews: