3940011 12.12
3.2 Exhaust Fan Installation
Note: For more detailed installation instructions, please see the RSV Chimney Fan installation and
operation manual provided with the fan.
If installing a RSV 400/450, remember to REMOVE the transport securing device before installing.
Mount the fan on a steel chimney adapter (SCA), roof curb and cap or another method that provides
external support. Do not use the vertical common vent to support the weight of the fan.
To mount the fan on the a roof curb and cap:
1. A roofer must install the roof curb on the roof.
2. Place the cap on the curb and apply a silicone on the top
curb cap.
3. Center the fan over the outlet hole and place on the curb cap
4. Open the fan housing and secure the fan to the cap and
curb using self-tapping sheet metal screws or lag bolts.
5. Apply another bead of silicone around the perimiter of the
fan. Do NOT block the 4 drain holes, located on each side of
the
base.
To mount the fan on a SCA:
1. Insert the SCA into the vent (see Fig. 4). If necessary, secure
the adapter to the vent wall using long sheet metal screws.
2. Place high-temperature silicone on top of the adapter.
3. Center the fan over the cutout and place on the silicone.
4. Open the fan housing and secure onto the adapter through the
pre-drilled holes in the bottom of each corner. Use lag bolts or
self-tapping sheet metal screws.
5. Apply a bead of silicone around the perimeter of the fan. Do not
block the (4) drain holes, located on each side of the base.
6. If necessary, provide external support from the roof to the
adapter/fan.
PROPRIETARY AND
CONFIDENTIAL
The information contained in this
drawing is the sole property of
EXHAUSTO, Inc. Any reproduction
in part or as a whole with out the
express written consent of
EXHAUSTO, Inc. is prohibited.
1200 Northmeadow Pkwy
Suite 180
Roswell, GA 30076
(770)587-3238
Fax (770)587-4731
TITLE
DATE
DRAWN
P/N
SHEET
1 OF 1
JMK
8/5/2008
curb asm
instructions
TOLERANCES
DIMENSIONS ARE IN INCHES AND
TOLERANCES ARE AS FOLLOWS
UNLESS OTHERWISE SPECIFIED.
DECIMALS ANGLES
0.0 =
C
0.030
C
1/2
a
0.00 =
C
0.010
0.000 =
C
0.005
MATERIAL
Fig. 3
Fig. 2
Fig. 4