ASSEMBLY AND USER MANUAL

 

 

 

 

 

 

 

SOLAR BLOCK ULTRA 

 

32

 

www.energie.pt 

 

10.

 

CONTROL PANEL  

The control terminal is installed on the front of the machine. 

The implemented control software guarantees an efficient equipment management and all the safety 
features of the machine. 

Through the terminal you can monitor the operation of the unit and set the operating parameters such 
as setpoint, time setting, etc.  

keyboard 

 

The terminal, shown in the figure below, has six buttons, with the following functions: 
 

 

Alarm  

Alarm Shows the list of active alarms and allows access to the alarm 
history; 

 

Menu  

Menu Allows you to enter the function tree of the main menu; 

 

Esc  

Esc Returns to top-level mask. 

 

Up  

Up Scrolls up or increases the value displayed by the cursor; 

 

Enter  

Enter Enters the selected submenu or confirms the set value; 

 

Down  

Down Scrolls down or reduces the value displayed by the cursor; 

 
The LED associated with the key has the following function:  
 

LED 

key 

Description 

Red 

 

Intermittent: Presence of active alarms

 

 

 

 

Summary of Contents for SB 12 ULTRA

Page 1: ...Thermodynamic Solar System Solar Block ULTRA CH Solar Block ULTRA PLUS CH DHW EN CENTRAL HEATING DOMESTIC HOT WATER Review 2 Version 0 Date 04 03 2021 Directives 2014 35 UE 2014 30 UE According Europe...

Page 2: ...ASSEMBLYANDUSERMANUAL SOLAR BLOCK ULTRA 2 www energie pt Directivas 2006 95 CE...

Page 3: ...r panel 8 3 5 2 Thermodynamic Solar Block 8 3 5 3 Unit storage 8 4 THERMODYNAMIC SOLAR BLOCK 9 4 1 Operation 9 4 2 Components 9 5 TECHNICAL SPECIFICATIONS 10 5 1 Solar Block 6 ULTRA 10 5 2 Solar block...

Page 4: ...ection of the panels to the Solar Block 24 6 3 6 Leak test 24 6 3 7 Vacuum 25 6 3 8 Refrigerant load 25 7 ULTRA PLUS SOLAR BLOCK ACTIVATE DHW BACKUP RESISTANCE 26 8 ULTRA SOLAR BLOCK ACTIVATE DHW CONT...

Page 5: ...product without any prior notice Our services are always at your disposal Feel free to call upon us 2 GENERALITY 2 1 Symbology The notes symbols shown can be found throughout the manual They are inte...

Page 6: ...are reduced or by people without any experience or knowledge unless they have been given supervision or instructions about use of the appliance by someone responsible for its safety Children must be s...

Page 7: ...ULTRA 115 SB 16 ULTRA 128 SB 32 ULTRA 135 SB 12 ULTRA PLUS 1880x752x1002 110x750x1000 230 SB 16 ULTRA PLUS 243 Table 1 Dimensions of the boxes pallets and respective weights 3 4 Transporting the unit...

Page 8: ...is the responsibility of the installer to strengthen the panel affixation structure 3 5 2 Thermodynamic Solar Block The Block installation site must be carefully designed And before carrying out any...

Page 9: ...nt fluid vapour of the panel raising the pressure and temperature thereof which is transmitted to the water circuit by way of a heat exchanger The heat exchanger is located inside the thermodynamic gr...

Page 10: ...1 Evaporator Thermodynamic solar panel Number 6 Material Aluminum surfece m 9 6 Refrigerante Type R410A Min load Kg 1 9 Hydraulic circuit Nominal flow m3 h 1 7 N of pumps 1 Typology EC Max power cons...

Page 11: ...r Thermodynamic solar panel Number 12 Material Aluminum surfece m 19 2 Refrigerante Type R410A Min load Kg 3 5 Hydraulic circuit Nominal flow m3 h 1 6 N of pumps 1 Typology EC Max power consuption W 6...

Page 12: ...Thermodynamic solar panel Number 16 Material Aluminum surfece m 25 6 Refrigerante Type R410A Min load Kg 4 5 Hydraulic circuit Nominal flow m3 h 2 8 N of pumps 1 Typology EC Max power consuption W 60...

Page 13: ...vaporator Thermodynamic solar panel Number 32 Material Aluminum Surface m 51 2 Refrigerante Type R410A Min load Kg 7 Hydraulic circuit Nominal flow m3 h 6 5 N of pumps 1 Typology EC Max power consupti...

Page 14: ...ify the operationality of the equipment the installing technician must have at its disposal Multimeter Appliance for measuring temperature EVD display 6 2 Thermodynamic Solar Panel 6 2 1 Panel orienta...

Page 15: ...Solar block 16 20m Solar block 32 30m For Installations with a distance greater than those indicated must contact the Technical Dept 6 2 4 Unevenness Under normal circunstances the total maximum grad...

Page 16: ...panels on the side opposite the connections they should preferably not be completely stuck together preferably 20mm 6 2 6 Direction of the panels The direction of the panels is defined by the outlets...

Page 17: ...cordance with the representation indicated above with a red cross 6 2 7 Solar panels layout The relative position of the panels depends on the system to be installed the availability of the installati...

Page 18: ...hey must have a sturdy structure in line with the circumstances of the site Each panel must be secured at 6 points as a minimum The image below illustrates an example of the fixation used The fixation...

Page 19: ...e placed before the installation of the panels for the sake of convenience obstruction passage of distribution tubes behind the panels Only remove the tube protection cover at the time of connection t...

Page 20: ...connections at the collectors to be as simple as possible respecting the instructions in the event of any unevenness It is essential for the copper tubes used to be refrigerant type CUDHP according t...

Page 21: ...gards the rear panel of the equipment and the installation site the installer must respect a minimum distance of 150mm to allow easy access to the hydraulic and refrigerant connections The installatio...

Page 22: ...www energie pt 6 3 3 Connections SB ULTRA and SB ULTRA PLUS The back of the Thermodynamic Block has the various connections in accordance with the designation set out below A B D A C E F E F B G G BS...

Page 23: ...e now the following types of piping must be placed Liquid Outward to panels Aspiration Return from panels Before making the aforementioned connections it is best to carry out the connections of the pa...

Page 24: ...and the whole refrigerant fluid loading process 6 3 5 Inlet Outlet connection of the panels to the Solar Block The ULTRA ULTRA PLUS Solar Block leaves the factory with nitrogen loading 30bar Take car...

Page 25: ...p are closed The vacuum manometer must always have the same display after stopping the pump thereby ensuring that the installation maintains the vacuum After vacuuming do not remove the hoses until th...

Page 26: ...of the equipment to the socket 230V The resistance has an integrated thermostat that is regulated to heat the water up to 55 C 8 ULTRA SOLAR BLOCK ACTIVATE DHW CONTROL The ULTRA Solar Block is set by...

Page 27: ...lustrates the type of filter to be used When the circuit is properly connected fill the hydraulic circuit and as this operation is being undertaken you must purge all the circuits ensuring that you el...

Page 28: ...K ULTRA 28 www energie pt 9 1 Hydraulic connection BS ULTRA Central Heating 9 2 Hydraulic connection BS ULTRA DHW It is recommended to install a thermostatic mixing valve in the DHW circuit according...

Page 29: ...ASSEMBLYANDUSERMANUAL SOLAR BLOCK ULTRA www energie pt 29 9 3 Hydraulic connection BS ULTRA CH DHW CH...

Page 30: ...valve in the DHW circuit according to the following diagram These hydraulic drawings just show the core parts and main principle of the application DHW output Shut off Valve Thermostatic Mixing Valve...

Page 31: ...the table below The maximum admissible losses for a cable of no more than 5 metres have already been considered in the calculations Single phase cable section mm2 Three phase cable section mm2 SB 6 UL...

Page 32: ...board The terminal shown in the figure below has six buttons with the following functions Alarm Alarm Shows the list of active alarms and allows access to the alarm history Menu Menu Allows you to ent...

Page 33: ...ve circulating pump 4 Unit status 1 OFF Equipment on OFF 2 ON All functions are active The unit adjusts the parameters according to the active operating mode 3 ENERGY SAVE All functions are active The...

Page 34: ...cturer Each user sees only the parameters and menu options available for their respective access level Main menu function tree A Unit state ON OFF AUTO ENERGY SAVE DHW only HEATING DHW B Setpoint Nomi...

Page 35: ...ched on in any other mode If the digital input is active ON status the equipment can be switched on or off through the console 2 The selected options can be HEATING DHW central heating domestic hot wa...

Page 36: ...the equipment is only effectively assumed if the equipment is in auto mode Note The anti ice protection is guaranteed on OFF mode D Input Output In the main menu D you can check the physical status of...

Page 37: ...one menu that shows the equipment in the pLAN network Each device is followed by its network address for example uPC board 1 G Service The main menu G is divided into two parts the first a b c without...

Page 38: ...f the storage water heater circuit management Check probe ALA09 Compressor discharge temperature off or damaged Automatic Equipment on safe mode OFF Check probe ALA10 Suction temperature probe off or...

Page 39: ...n cable ALD04 Low overheating Manual Equipment on safe mode OFF Check if there is no obstruction in the air circulation in the external unit ALD05 Low suction temperature Manual Equipment on safe mode...

Page 40: ...BLYANDUSERMANUAL SOLAR BLOCK ULTRA 40 www energie pt 11 Param default 12 DC bus ripple 13 Data comms fault 14 Drive thermistor 15 Autotune fault 16 Drive disabled 17 Motor phase 18 Fan fault 19 Speed...

Page 41: ...manufacturer A repair under the warranty is not reason for an extension of its term Warranty Exclusions The warranty ceases to be effective when the apparatus is no longer connected used or assembled...

Page 42: ...rned after more than 15 days have passed since the purchase date of the apparatus ATTENTION Technical assistance costs even within the warranty period shall be supported by the customer Km and assista...

Page 43: ...ASSEMBLYANDUSERMANUAL SOLAR BLOCK ULTRA www energie pt 43 NOTE...

Reviews: