ASSEMBLY AND USER MANUAL
SOLAR BLOCK ULTRA
21
6.3.
Thermodynamic Block
6.3.1.
Installation site
The choice of site where the Thermodynamic Block is placed is very important and must be carried out
bearing mind a certain number of criteria such as:
•
Accessibility;
•
Proximity of the boiler, with the latter serving as a support system or even in the event of the
replacement thereof;
•
Avoid the possibility of vibration transmission;
•
Place anti-vibration supports between the appliance and the ground;
•
Position of the piping from the panels;
•
Protected from bad weather such as garages, cellars, attics etc.;
•
Allow any possible assistance intervention.
As regards the rear panel of the equipment and the installation site the installer must respect a
minimum distance of 150mm to allow easy access to the hydraulic and refrigerant connections.
The installation of the Block near bedrooms should be avoided owing to the possible
transmission of vibrations and noise.
If the block is placed in the attic special care must be taken as regards the vibrations produced
under the wooden construction. Also provide for the placement of a tray under the appliance
in accordance with legislation to collect any water in the event of an installation rupture.
Never grab nor handle the Thermodynamic Block by the refrigerant or hydraulic connections.
6.3.2.
Dimensions
The external dimensions of the equipment depend on the configuration (Ultra or Ultra Plus). The
following figures show the external dimensions of the equipment.