ASSEMBLY AND USER MANUAL
SOLAR BLOCK ULTRA
15
However, you may install the panels with another inclination in certain situations.
6.2.3.
Distance
The maximum distance between the panels and the Thermodynamic Block depends on certain factors
such as the equipment model, the no. of curves, the piping diameter etc.
However, we would recommend that the distance should not exceed the following values:
•
Solar block 6 and 12 → 15m;
•
Solar block 16 → 20m;
•
Solar block 32 →30m.
For Installations with a distance greater than those indicated must contact the Technical Dept.
6.2.4.
Unevenness
Under normal circunstances the total maximum gradient must always be less than 15 mts.
However, there are situations where it is not possible to respect these distances, in these cases you
must consult our technical department.
The aspiration piping must rise above the level of the panels, in the same way as the distribution shaft
in order to avoid the rapid siphon effect of the liquid when the compressor stops.