5
the building through the ventilation unit. The felt ensures an even flow of air through the back
absorber and its roughness creates a turbulent flow of air which results in increased efficiency.
2.4 Insulation
Very little insulation is needed with the Luba
GL collector system. The only insulation is at the
bottom and top of the collector where no fresh air is admitted. The insulation used is a 25 mm (1”)
rigid polystyrene board.
Table 2: Absorber properties
Felt
Perforated plate
Composition
100% polyester
1020 grade steel
Coating
N/A
Black matt paint/light gray baked enamel
Density
0,35 kg/m
3
N/A
Thickness
3mm
Gauge 26 (0,0179 in./ 0,45 mm)
Fiber bonding
Needlepunching
N/A
Tension resistance
250 N
N/A
Porosity
N/A
1,6% (std) in relation to absorber area