Operate power generator ESE 604 DHG DIN
42
ESE 604 DHG (ES) DIN
Status: October 2018
4.6
Connecting up to consumers
Proceed as follows to connect appliances to the generator.
The following requirements must be met:
generator started
protective earthing conductor tested
device switched off
WARNING!
Electric shocks cause injury or death.
Do not earth the generator.
Do not connect protective conductor to an existing poten-
tial equalisation line.
Do not connect the generator to an existing electrical grid.
You can connect devices using Schuko or CEE sockets.
Fig. 4-4: Connecting up to consumers
Proceed as follows to connect a device to the control
panel:
1.
Unscrew covering on the socket.
2.
Push the plug into the socket.
The consumer is connected to the generator.
Switch the consumer on as follows:
1.
Switch consumer on.
Requirements
Connecting up to
consumers
Connecting up to
consumers
Switching the consumer
on