![Endress ESE 1308 DBG ES DUPLEX SILENT Operating Instructions Manual Download Page 74](http://html1.mh-extra.com/html/endress/ese-1308-dbg-es-duplex-silent/ese-1308-dbg-es-duplex-silent_operating-instructions-manual_2407078074.webp)
Troubleshooting
Version: May 2011
ESE 808 / 1308 / 1408 DBG ES DU PLEX SILENT
74
Malfunction
Possible cause
Correction
The test tip is not touching
a metallic blank location on
the consumer.
Hold the test tip on a metallic
blank location
Test lamp is defective
Call service staff.
The protective conductor is
defective.
Disconnect the consumer
from the generator.
The protective conductor is
missing.
Select the consumer with
a protective conductor.
Faults on the special equipment
The remote start equipment
connecting plug is not
inserted properly.
Insert the remote start
equipment connecting plug
correctly.
The automatic choke lifting
magnet is defective.
Call service staff.
The engine does not start in
remote start mode.
The remote start equipment
fuse is defective.
Replace the fuse.
The external start equipment
plug is not inserted properly.
Insert the external start
equipment plug correctly.
The engine does not start in
external start mode.
The high performance
external start fuse is
defective.
Replace the fuse.
The charge retention plug is
not inserted properly.
Insert the charge retention
plug correctly.
The battery is not charging in
charge retention mode.
The charge retention fuse is
defective.
Replace the fuse.
Rocker switch is in the OFF
position.
Set the rocker switch to the
ON position.
The engine does not run for
5 minutes.
Wait for the minimum running
time since an engine start.
There is a load / electrical
consumer switched in.
Switch off load / electrical
consumer.
Idling speed reduction does
not work.
The lifting magnet for speed
lowering in idle is defective.
Call service staff.
Table 7.1: Problems during generator operation