![Endress ESE 1308 DBG ES DUPLEX SILENT Operating Instructions Manual Download Page 65](http://html1.mh-extra.com/html/endress/ese-1308-dbg-es-duplex-silent/ese-1308-dbg-es-duplex-silent_operating-instructions-manual_2407078065.webp)
Maintenance
Maintenance plan
Version: May 2011
ESE 808 / 1308 / 1408 DBG ES DU PLEX SILENT
65
6 Maintenance
Maintenance of the generator is described in this section.
Only personnel of the manufacturer may carry out
maintenance or repair work not described in this section.
6.1 Maintenance plan
The maintenance work specified in this summary must be
carried out after the indicated time intervals.
Time interval in operating hours [h]
Maintenance work
after
8 h
every
8 h /
daily
every
25 h /
annually
every
50 h /
annually
every
100 h /
annually
annually
Check the electrical safety
before each start-up
Check the oil level
X
Changing the oil
X
(X)
1)
Change oil filter
X
Clean air filter
(X)
2)
Clean area around mufflers,
linkages, and springs
X
Exchange spark plugs
X
Change the fuel filter
X
Check fit of screws, nuts,
and bolts
X
Check condition and tightness
of the fuel hoses and
connections.
X
Table 6.1: Generator maintenance plans
1) When operating under a heavy load or at high environmental
temperatures at short intervals.
2) Clean more frequently when used in a dusty environment or in the
presence of foreign particles in the air or for longer use in high,
dry grass.