10.6.2
Write protection via write protection switch
The write protection switch makes it possible to block write access to the entire
operating menu with the exception of the following parameters:
• External pressure
• External temperature
• Reference density
• All parameters for configuring the totalizer
The parameter values are now read only and cannot be edited any more:
• Via service interface (CDI)
• Via HART protocol
• Via Modbus RS485
• Via service interface (CDI-RJ45)
• Via Ethernet network
• Via PROFIBUS DP
For device version with HART and Modbus RS485 communication types
OFF
ON
1 - Write protection
2 - Not used
3 - Not used
4 - Bus termination
A0017954
For device version with EtherNet/IP communication type