Proline Promass A 100
Installation
Hauser
19
Dimensions in SI units
DN
A
B
C
D
E
F
G
[mm]
[mm]
[in]
[in]
[mm]
[mm]
[mm]
[mm]
1
Approx.42
AF 1
½ NPT
77.0
70.0
47.0
178
2
Approx.42
AF 1
½ NPT
77.0
70.0
47.0
260
4
Approx.42
AF 1
½ NPT
83.0
83.0
59.5
385
Dimensions in US units
DN
A
B
C
D
E
F
G
[in]
[in]
[in]
[in]
[in]
[in]
[in]
[in]
¹⁄₂₄
Approx.
1.65
AF 1
½ NPT
3.0
2.8
1.85
7.01
¹⁄₁₂
Approx.
1.65
AF 1
½ NPT
3.0
2.8
1.85
10.24
¹⁄₈
Approx.
1.65
AF 1
½ NPT
3.3
3.2
2.34
15.16
For detailed information about using a rupture disk, refer to the Operating
Instructions for the device on the CD-ROM provided
Wall mounting
!
WARNING
Incorrect sensor mounting
Risk of injury if measuring tube breaks
‣
The sensor should never be installed in a pipe in a way that it is freely suspended
‣
Using the base plate, mount the sensor directly on the floor, wall or ceiling.
‣
Support the sensor on a securely mounted support base (e.g. angle bracket).
The following mounting versions are recommended for the installation.
Vertical
• Mounted directly on a wall using the base plate, or
• Device supported on an angle bracket mounted on the wall
Summary of Contents for Proline Promass A 100
Page 13: ...Proline Promass A 100 Storage and transport Endress Hauser 13 A0015604 A0015605...
Page 54: ......
Page 55: ......
Page 56: ...www addresses endress com...