Installation
Proline Promass 80
6
Hauser
The following mounting locations should be
avoided
:
• At the highest point in a pipe (risk of air accumulating)
• In an open down pipe directly upstream from a free pipe outlet. For ways of using the
measuring device in down pipes, see the related Operating Instructions on the CD-ROM.
2.2.3 Orientation
• The direction of the arrow on the nameplate of the measuring device must match the flow
direction of the fluid.
• The following table lists the possible orientations of the measuring devices:
Vertical
Horizontal
Horizontal
A0004572
A0004576
A0004576
Transmitter at the side
Transmitter at the top
Transmitter at the
bottom
Promass A
Recommended
Possible (
m
)
Possible (
m
,
p
)
Promass E
Recommended
Recommended (
n
)
Recommended (
o
,
p
)
Promass F
Recommended
Recommended (
n
)
Recommended (
o
,
p
)
Promass F HT*
Compact version
Recommended
Not suitable
Recommended (
o
,
p
)
Promass F HT*
Remote version
Recommended
Possible (
n
)
Recommended (
o
,
p
)
Promass H
Recommended
Recommended
Recommended (
p
)
Promass I
Recommended
Recommended
Recommended (
p
)
Promass P
Recommended
Recommended
Recommended (
p
)
Promass S
Recommended
Recommended
Recommended (
p
)
*HT = high temperature version for medium temperatures (TM) > 200 °C (> 392 °F)
m
Do
not
install the measuring device in such a way that is suspended without any support or securing unit.
n
This orientation is
not suitable
for fluids with entrained solids.
o
This orientation is
not suitable
for outgassing fluids.
p
This orientation is
not suitable
for low fluid temperatures.