Nivotester FTR525
Hauser
31
Commissioning
8�4�1�7 Manual adjustment upper limit (UL) motion detection
Application
2000
→
Sensor
2100
→
Motion detection
2120
→
Manual adjustment UL
2123
This function can be used to change the upper limit of the set detection range of the
motion detection (function
2113
→ 29).
8�4�1�8 Movement detection damping
Application
2000
→
Sensor
2100
→
Motion detection
2120
→
Damping
2124
This function can be used to enter a damping of the movement detection (function
2114
→ 30).
8�4�1�9 Parallel mode
Application
2000
→
Sensor
2100
→
Parallel mode
2130
In order to prevent mutual interference from multiple microwave barriers operated in
parallel, up to five different channels can be set.
Options: "Channel 1" to "Channel 5"
Channel 1
Channel 2
Channel 3
21 Parallel mode of Soliwave FQR57/FDR57
• For details regarding the Soliwave microwave barriers, please see the associated
Technical Information TI01330F/97/EN and Operating Instructions
BA01804F/97/A2.
• It is not necessary to carry out the channel setting again after changing the FQR57/
FDR57 devices, as the selected channel is automatically transmitted from the
FTR525 to the FQR57 transmitter and the FDR57 transceiver.